Vertiv Liebert GXT5 8000IRT5UXLN, 8000VA 8000W 230V, Double Conversion, 1.0 PF, 5U Rack/Tower, 4x C13, 4x C19, Single Phase, RDU101 SNMP included
| Features | |
| UPS topology The two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances. | Double-conversion (Online) |
| Output power capacity The maximum power that the device can produce. | 8 kVA |
| Output power The power that the device can produce. | 8000 W |
| Waveform | Pure sine |
| Input operation voltage (min) The minumum voltage needed by the device during operation. | 176 V |
| Input operation voltage (max) The maximum input voltage supported by the device. | 288 V |
| Input frequency The frequency (Hz) which is required to power the product. | 40 - 70 Hz |
| Output operation voltage (min) The minumum voltage produced by the device during operation. | 230 V |
| Output operation voltage (max) The maximum output voltage produced by the device. | 240 V |
| Output frequency | 50/60 Hz |
| Output voltage regulation | 3% |
| Response time The response time is the time difference between the moment that a source (for example a video card) sends a signal and that equipment (for example a monitor) receives or display the signal. (Used abbreviations: R/F = Rise and Fall.) | 0 ms |
| Number of input phases | 1 |
| Number of output phases | 1 |
| Efficiency | 94.5% |
| Power factor | 1 |
| Input power factor | 0.99 |
| Output power factor | 1 |
| Emergency Power Off (EPO) |
|
| Noise level The amplitude level of the undesired background noise, usually measured in decibels (db). | 55 dB |
| Power protection features Features that protect the device against power problems e.g. overload. | Overload |
| Audible alarm(s) Alarms that make a sound when they are activated (set off). |
|
| Ports & interfaces | |
| AC outlet types The type of outlet for AC electricity. | C13 coupler, C19 coupler, IEC 320, Terminal |
| Power plug A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection. | Terminal |
| AC outlets quantity The number of sockets in the device where AC electrical power can be connected. | 8 AC outlet(s) |
| USB port The device features a socket into which a USB cable can be plugged. |
|
| Serial interface |
|
| Battery | |
| Typical backup time at full load The amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is fully loaded (100% of capacity). | 3.5 min |
| Typical backup time at half load The amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity). | 9.5 min |
| Hot-swap battery |
|
| Design | |
| Form factor The shape or design of the product. | Rackmount/Tower |
| Rack capacity The spase that device fill in rack. | 5U |
| Cooling type The method used to cool the device or to cool the air around the device. | Active |
| Product colour The colour e.g. red, blue, green, black, white. | Black |
| Display type Type of display (screen) e.g. LCD. | LCD |
| International Protection (IP) code The IP code classifies and rates the degree of protection provided against the intrusion (including body parts such as hands and fingers), dust, accidental contact, and water by mechanical casings and electrical enclosures. It is published by the International Electrotechnical Commission (IEC). The digits (characteristic numerals) indicate conformity with the conditions summarized in the tables below. Where there is no protection rating with regard to one of the criteria, the digit is replaced with the letter X. an electrical socket rated IP22 is protected against insertion of fingers and will not be damaged or become unsafe during a specified test in which it is exposed to vertically or nearly vertically dripping water. Another example is the Sony Xperia Z Ultra, one of the first cellular phones to be IP-rated; it is rated at IP58 and marketed as "dust resistant" and can be "immersed in 1.5 meter of freshwater for up to 30 minutes". | IP20 |
| Certificates | |
| Compliance certificates Indicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies. | RoHS |
| Certification | CE, EMI/EMC/C-Tick EMC, ESD |
| Packaging content | |
| Cables included | USB cable |
| Safety regulation & standards | |
| Safety List of regulatory safety standards for all countries in which this product has been certified. | IEC62040-1:2008 |
| Weight & dimensions | |
| Width The measurement or extent of something from side to side. | 430 mm |
| Depth The distance from the front to the back of something. | 630 mm |
| Height The measurement of the product from head to foot or from base to top. | 217 mm |
| Weight Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies. | 74.5 kg |
| Logistics data | |
| Country of origin Country where the device is made. Aka Country of manufacture (COM). | China |
| SKU | 808124 |
| MPN | 1201979 |
| Brand | Vertiv |
| Product Condition | Brand New/Unused |
| Stock Availability | Available for Shipping |
| Product Use | General |
| Warranty Period | 1 Year Warranty |
| Warranty Contact | https://www.vertiv.com/ |