Eaton ePDU G3 Metered 0U 1-Phase 24 Outlets 16A IEC-60309 PDU

Item No:
419090
MPN:
EMOB04
$2,317.87
Payment options

This product is currently not available!

Shipping Information
  • Unavailable for shipping
  • This product is not currently available for purchase
Store Availability
  • Unavailable at Bankstown Store
  • Unavailable at Castle Hill Store
  • Unavailable at Northmead Store
Eaton EMOB04, Metered, 0U, Vertical, Black, LCD, 24 AC outlet(s)
Meter the Input, branch, individual outlets & IT equipment across A and B feed

ePDU G3 Metered Outlet models allow device level metering over multiple power feeds, and includes kWh, peak power and current draw. Clearly view and understand the consumption of individual devices powered over A and B feeds and see available power. Metered Outlet units have no switching. They include IEC Class 1 (+/-1%) billing grade accuracy, an advanced hot-swap meter with LCD pixel display showing V, W, A and kWh, and the ability to daisy chain 8 ePDUs to share the same network connection and IP address.
Design
PDU types A power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing, and remote monitoring and control by LAN or SNMP. Metered
Rack capacity The spase that device fill in rack. 0U
Mounting What size the mounting head of the product is, to couple it with a camera. Vertical
Product colour The colour e.g. red, blue, green, black, white. Black
Display The description of display that can includes display type, resolution, size etc. LCD
Ports & interfaces
AC outlets quantity The number of sockets in the device where AC electrical power can be connected. 24 AC outlet(s)
Power plug A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection. IEC 60309
AC outlet types The type of outlet for AC electricity. C13 coupler,C19 coupler
Output connections 20 x C13 & 4 x C19
Features
LED indicators
Cable length How long the cable is. 3 m
RoHS compliance The Restriction of Hazardous Substances (RoHS) Directive aims to restrict certain dangerous substances commonly used in electrical and electronic equipment. Any RoHS compliant product is tested for the presence of Lead (Pb), Cadmium (Cd), Mercury (Hg), Hexavalent chromium (Hex-Cr), Polybrominated biphenyls (PBB), and Polybrominated diphenyl ethers (PBDE). PBB and PBDE are flame retardants used in several plastics. For Cadmium and Hexavalent chromium, there must be less than 0.01% of the substance by weight at raw homogeneous materials level. For Lead, PBB, and PBDE, there must be no more than 0.1% of the material, when calculated by weight at raw homogeneous materials. Any RoHS compliant component must have 100 ppm or less of mercury and the mercury must not have been intentionally added to the component. In the EU, some military and medical equipment are exempt from RoHS compliance.
Certification CB, CE, EN 60950-1:2006/A11:2009/A1:2010/A12:2011 IEC 60950-1(ed.2), IEC 60950-1(ed.2);am1 EN 55022:2010 EN 55024:2010 ISO 9001:2008 / ISO 14001:2004
Power
Nominal input voltage The voltage which the manufacturer recommends that the device needs to operate normally. 230 V
AC input frequency 50 Hz
Maximum current The greatest possible amount of current, which is a quantity representing the rate of flow of electric charge. 16 A
Weight & dimensions
Dimensions (WxDxH) Dimensions of the product (Width x Depth x Height). 53 x 1604 x 52 mm
More Information
SKU 419090
MPN EMOB04
Brand Eaton
Product Condition Brand New/Unused
Product Use General