Shipping Information
- Unavailable for shipping
- This product is not currently available for purchase
Store Availability
- Unavailable at Bankstown Store
- Unavailable at Castle Hill Store
- Unavailable at Northmead Store
Eaton EATS16, Basic, 1U, Rackmount, Horizontal, Black, LCD
Power Source Transfer Switch
Seamless power transfer
Eaton ATS are designed to provide power supply redundancy for single connection equipment. With ATS, power from two independent sources can be supplied to IT equipment, which have only one input power supply.
Redundancy
Only advanced servers are equipped with a dual electrical power supply. The majority of network devices and entry-level servershave a single connection with only one electrical power input.
With the Eaton ATS, critical equipment can be connected to a redundant power supply.
Both sources (primary and secondary) are connected in a straightforward manner to the ATS in the base of the rack.
The Eaton ATS then controls the redundancy of this electrical power supply. If the primary source fails, transfer to the secondary source is automatic and instantaneous.
Simple and cost-effective
Considering the advanced design of the Eaton ATS, these are highly competitive in price compared with the 'dual power supply' options available from suppliers of networking equipment. 1U high, the unit can be installed easily within the rack. Metering and basic configuration capabilities are possible through ATS 16's LCD.
Network connectivity
The ATS 16 Netpack and ATS 30 provide network connectivity.
This allows users to access, configure and manage units from
remote locations.
Seamless power transfer
Eaton ATS are designed to provide power supply redundancy for single connection equipment. With ATS, power from two independent sources can be supplied to IT equipment, which have only one input power supply.
Redundancy
Only advanced servers are equipped with a dual electrical power supply. The majority of network devices and entry-level servershave a single connection with only one electrical power input.
With the Eaton ATS, critical equipment can be connected to a redundant power supply.
Both sources (primary and secondary) are connected in a straightforward manner to the ATS in the base of the rack.
The Eaton ATS then controls the redundancy of this electrical power supply. If the primary source fails, transfer to the secondary source is automatic and instantaneous.
Simple and cost-effective
Considering the advanced design of the Eaton ATS, these are highly competitive in price compared with the 'dual power supply' options available from suppliers of networking equipment. 1U high, the unit can be installed easily within the rack. Metering and basic configuration capabilities are possible through ATS 16's LCD.
Network connectivity
The ATS 16 Netpack and ATS 30 provide network connectivity.
This allows users to access, configure and manage units from
remote locations.
| Design | |
| PDU types A power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing, and remote monitoring and control by LAN or SNMP. | Basic |
| Form factor The shape or design of the product. | Rackmount |
| Rack mounting The type of mounting that can position devices in a shelving system (rack). |
|
| Rack capacity The spase that device fill in rack. | 1U |
| Mounting What size the mounting head of the product is, to couple it with a camera. | Horizontal |
| Product colour The colour e.g. red, blue, green, black, white. | Black |
| Display The description of display that can includes display type, resolution, size etc. | LCD |
| Ports & interfaces | |
| AC outlets quantity The number of sockets in the device where AC electrical power can be connected. | 9 AC outlet(s) |
| Power plug A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection. | C20 coupler |
| AC outlet types The type of outlet for AC electricity. | C13 coupler,C19 coupler |
| Master AC outlets quantity | 9 |
| Features | |
| LED indicators |
|
| Certification | IEC/EN 62310-1, IEC/EN 60950-1, IEC/EN 62310-2, CE |
| Power | |
| Nominal input voltage The voltage which the manufacturer recommends that the device needs to operate normally. | 230 V |
| AC input frequency | 50/60 Hz |
| Maximum current The greatest possible amount of current, which is a quantity representing the rate of flow of electric charge. | 16 A |
| Maximum input current per phase | 16 A |
| Weight & dimensions | |
| Width The measurement or extent of something from side to side. | 440 mm |
| Depth The distance from the front to the back of something. | 250 mm |
| Dimensions (WxDxH) Dimensions of the product (Width x Depth x Height). | 430 x 250 x 43 mm |
| Height The measurement of the product from head to foot or from base to top. | 43 mm |
| Weight Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies. | 3.3 kg |
| Packaging content | |
| Rack mount kit |
|
| SKU | 420350 |
| MPN | EATS16 |
| Brand | Eaton |
| Product Condition | Brand New/Unused |
| Stock Availability | Available for Shipping |
| Product Use | General |
| Warranty Period | 2 Years Warranty |
| Warranty Contact | https://www.eaton.com/ |