| Features | |
| UPS topology The two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances. | Line-Interactive |
| Output power capacity The maximum power that the device can produce. | 3 kVA |
| Output power The power that the device can produce. | 2400 W |
| Waveform | Sine |
| Input operation voltage (min) The minumum voltage needed by the device during operation. | 176 V |
| Input operation voltage (max) The maximum input voltage supported by the device. | 276 V |
| Input frequency The frequency (Hz) which is required to power the product. | 40/70 Hz |
| Output operation voltage (min) The minumum voltage produced by the device during operation. | 200 V |
| Output operation voltage (max) The maximum output voltage produced by the device. | 240 V |
| Output frequency | 50/60 Hz |
| Output frequency regulation | 1 Hz |
| Maximum current The greatest possible amount of current, which is a quantity representing the rate of flow of electric charge. | 16 A |
| Surge energy rating A surge protector is an appliance designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. The surge energy rating is a measure of how much energy a surge protector can theoretically absorb in a single event, without failure. | 296 J |
| Number of input phases | 1 |
| Power factor | 0.99 |
| Crest factor | 3:1 |
| Noise level The amplitude level of the undesired background noise, usually measured in decibels (db). | 47 dB |
| Audible alarm(s) Alarms that make a sound when they are activated (set off). |
|
| Power source type What the power source is. | AC |
| Detachable power cord |
|
| Ports & interfaces | |
| AC outlet types The type of outlet for AC electricity. | C13 coupler, C19 coupler |
| Power plug A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection. | C20 coupler |
| AC outlets quantity The number of sockets in the device where AC electrical power can be connected. | 10 AC outlet(s) |
| USB port The device features a socket into which a USB cable can be plugged. |
|
| USB 2.0 ports quantity Number of USB 2.0 ports (connecting interfaces) in the device. USB 2.0 was released in April 2000 (now called "Hi-Speed"), adding higher maximum signaling rate of 480 Mbit/s (effective throughput up to 35 MB/s or 280 Mbit/s), USB 2.0 ports are usually black. | 1 |
| Serial interface |
|
| Serial interface type | RS-232 |
| RS-232 ports The number of sockets (ports) for RS-232. An RS-232 serial port was once a standard feature of a personal computer, used for connections to modems, printers, mice, data storage, uninterruptible power supplies, and other peripheral devices. Now it has been largely replaced by USB and other ports. | 1 |
| Ethernet LAN (RJ-45) ports Number of Ethernet LAN (RJ-45) ports (connecting interfaces) in the device. Ethernet LAN (RJ-45) ports allow a computer to connect to the ethernet. | 1 |
| Cabling technology Type of cable technology performance. | 10/100Base-T |
| Battery | |
| Battery technology The type of battery in the device, e.g. nickel–cadmium (NiCd). | Lithium-Ion (Li-Ion) |
| Battery capacity The amount of electric charge a battery can deliver at the rated voltage. The more electrode material contained in the cell the greater its capacity. A small cell has less capacity than a larger cell with the same chemistry, although they develop the same open-circuit voltage. Capacity is measured in units such as amp-hour (A·h). | 9 Ah |
| Battery voltage The voltage (V) of the battery. | 76.8 V |
| Battery life (max) | 8 year(s) |
| Charging current | 1.7 A |
| Hot-swap battery |
|
| Cold start |
|
| Design | |
| Form factor The shape or design of the product. | Rackmount/Tower |
| Rack capacity The spase that device fill in rack. | 2U |
| Cooling type The method used to cool the device or to cool the air around the device. | Active |
| Built-in fan |
|
| Product colour The colour e.g. red, blue, green, black, white. | Black |
| Control type The way in which the device is controlled. | Buttons |
| Display type Type of display (screen) e.g. LCD. | LCD |
| Certification | IEC/EN 62040-1, IEC/EN 62040-2 Cat C1, IEC/EN 62040-3, UL 1778, CSA 22.2, CISPR22 Class B, FCC part 15 Class B, CE, CB, EAC |
| Operational conditions | |
| Operating temperature (T-T) The minimum and maximum temperatures at which the product can be safely operated. | 0 - 40 °C |
| Storage temperature (T-T) The minimum and maximum temperatures at which the product can be safely stored. | -25 - 55 °C |
| Operating relative humidity (H-H) | 0 - 95% |
| Operating altitude | 0 - 1500 m |
| Non-operating altitude | 1500 - 3000 m |
| Weight & dimensions | |
| Width The measurement or extent of something from side to side. | 440 mm |
| Depth The distance from the front to the back of something. | 605 mm |
| Height The measurement of the product from head to foot or from base to top. | 86.5 mm |
| Weight Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies. | 22.8 kg |
| SKU | 535004 |
| MPN | 9PX3000IRTANZ-L |
| Brand | Eaton |
| Product Condition | Brand New/Unused |
| Stock Availability | Available for Shipping |