CyberPower Online S Rackmount Tower 1000VA/9000W Online Double Conversion UPS
Item No:
345632
MPN:
OLS10000ERT6UM
$6,428.87
Payment options
Shipping Information
- Unavailable for shipping
- This product is not currently available for purchase
Store Availability
- Unavailable at Bankstown Store
- Unavailable at Castle Hill Store
- Unavailable at Northmead Store
CyberPower UPS OLS10000ERT6UM, 1-way
CYBERPOWER Online S 10000VA/9000W Rackmount UPS - 12V/7AH*20 - Hardwire Terminal Block, USB & Serial Port & SNMP Slot(OLS10000ERT6UM)2 Yrs Adv. Replacement WTY
| Features | |
| UPS topology The two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances. | Double-conversion (Online) |
| Output power capacity The maximum power that the device can produce. | 10000 VA |
| Output power The power that the device can produce. | 9000 W |
| Waveform | Pure sine |
| Input operation voltage (min) The minumum voltage needed by the device during operation. | 110 V |
| Input operation voltage (max) The maximum input voltage supported by the device. | 276 V |
| Input frequency The frequency (Hz) which is required to power the product. | 50/60 Hz |
| Output operation voltage (min) The minumum voltage produced by the device during operation. | 208 V |
| Output operation voltage (max) The maximum output voltage produced by the device. | 240 V |
| Output frequency | 50/60 Hz |
| Output voltage regulation | 0.1% |
| Surge energy rating A surge protector is an appliance designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. The surge energy rating is a measure of how much energy a surge protector can theoretically absorb in a single event, without failure. | 445 J |
| Number of output phases | 1 |
| Efficiency (ECO mode) | 96% |
| Power factor | 0.9 |
| Input power factor | 0.99 |
| Crest factor | 3:1 |
| ECO mode |
|
| Ports & interfaces | |
| AC outlets quantity The number of sockets in the device where AC electrical power can be connected. | 1 AC outlet(s) |
| USB port The device features a socket into which a USB cable can be plugged. |
|
| Serial interface |
|
| Serial interface type | RS-232 |
| RS-232 ports The number of sockets (ports) for RS-232. An RS-232 serial port was once a standard feature of a personal computer, used for connections to modems, printers, mice, data storage, uninterruptible power supplies, and other peripheral devices. Now it has been largely replaced by USB and other ports. | 1 |
| Design | |
| Form factor The shape or design of the product. | Rackmount/Tower |
| Housing material What the casing of the product is made of. | Metal |
| Product colour The colour e.g. red, blue, green, black, white. | Black |
| LED indicators |
|
| Display The description of display that can includes display type, resolution, size etc. | LCD |
| RoHS compliance The Restriction of Hazardous Substances (RoHS) Directive aims to restrict certain dangerous substances commonly used in electrical and electronic equipment. Any RoHS compliant product is tested for the presence of Lead (Pb), Cadmium (Cd), Mercury (Hg), Hexavalent chromium (Hex-Cr), Polybrominated biphenyls (PBB), and Polybrominated diphenyl ethers (PBDE). PBB and PBDE are flame retardants used in several plastics. For Cadmium and Hexavalent chromium, there must be less than 0.01% of the substance by weight at raw homogeneous materials level. For Lead, PBB, and PBDE, there must be no more than 0.1% of the material, when calculated by weight at raw homogeneous materials. Any RoHS compliant component must have 100 ppm or less of mercury and the mercury must not have been intentionally added to the component. In the EU, some military and medical equipment are exempt from RoHS compliance. |
|
| Operational conditions | |
| Operating temperature (T-T) The minimum and maximum temperatures at which the product can be safely operated. | 0 - 40 °C |
| Storage temperature (T-T) The minimum and maximum temperatures at which the product can be safely stored. | -15 - 45 °C |
| Operating relative humidity (H-H) | 0 - 90% |
| Storage relative humidity (H-H) | 0 - 95% |
| Operating altitude | 0 - 2000 m |
| Non-operating altitude | 0 - 15000 m |
| Weight & dimensions | |
| Width The measurement or extent of something from side to side. | 438 mm |
| Depth The distance from the front to the back of something. | 680 mm |
| Height The measurement of the product from head to foot or from base to top. | 130.5 mm |
| Weight Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies. | 20 kg |
| SKU | 345632 |
| MPN | OLS10000ERT6UM |
| Brand | Cyberpower |
| Product Condition | Brand New/Unused |
| Stock Availability | Available for Shipping |
| Product Use | General |