CyberPower OR600ERM1U, Line-Interactive, 600 VA, 360 W, Sine, 165 V, 271 V
CyberPower OR600ERM1U Line-Interactive UPS offers Simulated Sine Wave output power for office system devices including PCs, workstations, networking devices, and peripherals. It's typically integrated in the back office, server room, and data center environment to ensure a reliable backup power supply during power failures. In addition, the rackmount / tower convertible design gives it enhanced flexibility for installation and operation in almost any environment.

The UPS has a multifunction LCD display which offers real-time information, including input and output voltage levels, load and battery levels, battery runtime, overload warning, and a silent mode. With the network ports on the UPS, it prevents network devices from being subjected to sudden power surges caused by lightning, thereby avoiding potential system damage. As for battery maintenance, the UPS allows battery hot-swapping, which enables users to perform normal battery maintenance without significant interruption.
Features
UPS topology The two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances. Line-Interactive
Output power capacity The maximum power that the device can produce. 600 VA
Output power The power that the device can produce. 360 W
Waveform Sine
Input operation voltage (min) The minumum voltage needed by the device during operation. 165 V
Input operation voltage (max) The maximum input voltage supported by the device. 271 V
Input frequency The frequency (Hz) which is required to power the product. 50/60 Hz
Output operation voltage (max) The maximum output voltage produced by the device. 230 V
Output frequency 50/60 Hz
Automatic Voltage Regulation (AVR)
Power factor 0.6
EMI/RFI noise filtering
Surge protection
Surge protection features Digital Subscriber Line (DSL),Fax,Modem,Network,Telephone
Power protection features Features that protect the device against power problems e.g. overload. Overload
Audible alarm(s) Alarms that make a sound when they are activated (set off).
Audible alarm modes Low battery alarm,Overload alarm
Ports & interfaces
AC outlet types The type of outlet for AC electricity. C13 coupler
Power plug A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection. C14 coupler
AC outlets quantity The number of sockets in the device where AC electrical power can be connected. 6 AC outlet(s)
USB port The device features a socket into which a USB cable can be plugged.
Battery
Battery technology The type of battery in the device, e.g. nickel–cadmium (NiCd). Sealed Lead Acid (VRLA)
Hot-swap battery
Design
Form factor The shape or design of the product. Rackmount
Rack capacity The spase that device fill in rack. 1U
Cable length How long the cable is. 1.83 m
Product colour The colour e.g. red, blue, green, black, white. Silver
Display The description of display that can includes display type, resolution, size etc. LCD
RoHS compliance The Restriction of Hazardous Substances (RoHS) Directive aims to restrict certain dangerous substances commonly used in electrical and electronic equipment. Any RoHS compliant product is tested for the presence of Lead (Pb), Cadmium (Cd), Mercury (Hg), Hexavalent chromium (Hex-Cr), Polybrominated biphenyls (PBB), and Polybrominated diphenyl ethers (PBDE). PBB and PBDE are flame retardants used in several plastics. For Cadmium and Hexavalent chromium, there must be less than 0.01% of the substance by weight at raw homogeneous materials level. For Lead, PBB, and PBDE, there must be no more than 0.1% of the material, when calculated by weight at raw homogeneous materials. Any RoHS compliant component must have 100 ppm or less of mercury and the mercury must not have been intentionally added to the component. In the EU, some military and medical equipment are exempt from RoHS compliance.
Operational conditions
Operating temperature (T-T) The minimum and maximum temperatures at which the product can be safely operated. 0 - 40 °C
Storage temperature (T-T) The minimum and maximum temperatures at which the product can be safely stored. -15 - 45 °C
Operating relative humidity (H-H) 0 - 95%
Storage relative humidity (H-H) 0 - 95%
Operating altitude 0 - 3048 m
Weight & dimensions
Width The measurement or extent of something from side to side. 433 mm
Depth The distance from the front to the back of something. 235 mm
Height The measurement of the product from head to foot or from base to top. 44 mm
Weight Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies. 7.8 kg
Packaging data
Package width The distance from one side of the packaging to the other. 530 mm
Package depth The distance from the front to the back of the packaging. 315 mm
Package height The distance from the top to the bottom of the packaging. 155 mm
Package weight Weight of the packaged product. 10.3 kg
More Information
SKU 461594
MPN OR600ERM1U
Brand Cyberpower
Product Condition Brand New/Unused
Stock Availability Available for Shipping
Product Use General
Warranty Period 2 Years Warranty
Warranty Contact https://www.cyberpowersystems.com/