Skip to content

CyberPower Professional Rackmount/Tower 1000VA 1000W Line-Interactive UPS

Item No:
347662
MPN:
PR1000ERT2U
$749.00
Payment options

This product is currently not available!

Shipping Information
  • Unavailable for shipping
  • This product is not currently available for purchase
Store Availability
  • Unavailable at Bankstown Store
  • Unavailable at Castle Hill Store
  • Unavailable at Northmead Store
CyberPower PR1000ERT2U, Line-Interactive, 1000 VA, 1000 W, Pure sine, 159 V, 288 V
CyberPower PR1000ERT2U Line-Interactive UPS, with seamless Pure Sine Wave, provides the best power protection available for office system devices including PCs, workstations, networking devices, and peripherals. It's typically integrated in the back office, server room, and data center environment. The rackmount / tower convertible design gives it enhanced flexibility for installation and operation in almost any environment.

Multiple UPS systems can be connected to a single main Emergency Power Off (EPO) switch. In the event of an emergency, the UPS systems can be shut down immediately with the EPO button. As for battery maintenance, the UPS allows battery hot-swapping, which enables users to perform normal battery maintenance without significant interruption.
Features
UPS topology The two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances. Line-Interactive
Output power capacity The maximum power that the device can produce. 1000 VA
Output power The power that the device can produce. 1000 W
Waveform Pure sine
Input operation voltage (min) The minumum voltage needed by the device during operation. 159 V
Input operation voltage (max) The maximum input voltage supported by the device. 288 V
Input frequency The frequency (Hz) which is required to power the product. 50/60 Hz
Output operation voltage (min) The minumum voltage produced by the device during operation. 220 V
Output operation voltage (max) The maximum output voltage produced by the device. 240 V
Automatic Voltage Regulation (AVR)
Surge energy rating A surge protector is an appliance designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. The surge energy rating is a measure of how much energy a surge protector can theoretically absorb in a single event, without failure. 2430 J
Response time The response time is the time difference between the moment that a source (for example a video card) sends a signal and that equipment (for example a monitor) receives or display the signal. (Used abbreviations: R/F = Rise and Fall.) 4 ms
Number of input phases 1
Number of output phases 1
Power Factor Correction (PFC) type Active
EMI/RFI noise filtering
Noise level The amplitude level of the undesired background noise, usually measured in decibels (db). 52.5 dB
Surge protection
Surge protection features Network
Power protection features Features that protect the device against power problems e.g. overload. Overload
Audible alarm(s) Alarms that make a sound when they are activated (set off).
Web-based management Using a website/web application to manage something.
Management protocols SNMP/HTTP
Audible alarm modes Low battery alarm,Overload alarm
Ports & interfaces
AC outlet types The type of outlet for AC electricity. C13 coupler
Power plug A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection. C14 coupler
AC outlets quantity The number of sockets in the device where AC electrical power can be connected. 10 AC outlet(s)
USB port The device features a socket into which a USB cable can be plugged.
Serial interface
Serial interface type RS-232
Ethernet LAN (RJ-45) ports Number of Ethernet LAN (RJ-45) ports (connecting interfaces) in the device. Ethernet LAN (RJ-45) ports allow a computer to connect to the ethernet. 2
Emergency Power Off (EPO) connector
Battery
Battery technology The type of battery in the device, e.g. nickel–cadmium (NiCd). Sealed Lead Acid (VRLA)
Number of batteries supported The number of batteries that can be used with the product. 1
Typical backup time at full load The amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is fully loaded (100% of capacity). 7 min
Typical backup time at half load The amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity). 21 min
Battery recharge time Approximate time required to recharge the battery from completely empty to completely full 3 h
Hot-swap battery
Replacement battery cartridge RBP0128
Design
Form factor The shape or design of the product. Rackmount/Tower
Housing material What the casing of the product is made of. Metal
Rack capacity The spase that device fill in rack. 2U
Cable length How long the cable is. 1.8 m
Product colour The colour e.g. red, blue, green, black, white. Black
LED indicators Fault,Power,Status
Display The description of display that can includes display type, resolution, size etc. LCD
Energy Star certified This indicates that the product is compliant with Energy Star, which is an international standard for energy-efficient consumer products.
RoHS compliance The Restriction of Hazardous Substances (RoHS) Directive aims to restrict certain dangerous substances commonly used in electrical and electronic equipment. Any RoHS compliant product is tested for the presence of Lead (Pb), Cadmium (Cd), Mercury (Hg), Hexavalent chromium (Hex-Cr), Polybrominated biphenyls (PBB), and Polybrominated diphenyl ethers (PBDE). PBB and PBDE are flame retardants used in several plastics. For Cadmium and Hexavalent chromium, there must be less than 0.01% of the substance by weight at raw homogeneous materials level. For Lead, PBB, and PBDE, there must be no more than 0.1% of the material, when calculated by weight at raw homogeneous materials. Any RoHS compliant component must have 100 ppm or less of mercury and the mercury must not have been intentionally added to the component. In the EU, some military and medical equipment are exempt from RoHS compliance.
Certification CE, FCC B, UL, RCM, VCCI
Operational conditions
Operating temperature (T-T) The minimum and maximum temperatures at which the product can be safely operated. 0 - 40 °C
Storage temperature (T-T) The minimum and maximum temperatures at which the product can be safely stored. -15 - 45 °C
Operating relative humidity (H-H) 0 - 95%
Storage relative humidity (H-H) 0 - 95%
Operating altitude 0 - 3000 m
Non-operating altitude 0 - 15000 m
Weight & dimensions
Width The measurement or extent of something from side to side. 433 mm
Depth The distance from the front to the back of something. 412 mm
Height The measurement of the product from head to foot or from base to top. 86.5 mm
Weight Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies. 22.4 kg
Packaging data
Cables included Serial,USB cable
Package width The distance from one side of the packaging to the other. 560 mm
Package depth The distance from the front to the back of the packaging. 530 mm
Package height The distance from the top to the bottom of the packaging. 275 mm
Package weight Weight of the packaged product. 29 kg
More Information
SKU 347662
MPN PR1000ERT2U
Brand Cyberpower
Product Condition Brand New/Unused
Stock Availability Available for Shipping
Product Use General
Warranty Period 3 Years Warranty
Warranty Contact https://www.cyberpowersystems.com/