CyberPower Online S Rackmount/Tower 10000VA 9000W Double-conversion UPS
Item No:
345583
MPN:
OL10000ERT3UP
$8,495.87
Payment options
Shipping Information
- Unavailable for shipping
- This product is not currently available for purchase
Store Availability
- Unavailable at Bankstown Store
- Unavailable at Castle Hill Store
- Unavailable at Northmead Store
CyberPower OL10000ERT3UP, Double-conversion (Online), 10000 VA, 9000 W, Pure sine, 180 V, 280 V
CyberPower OL10000ERT3UP is a high-performance UPS featuring online double-conversion topology, which provides seamless pure sine wave power for mission-critical devices such as NAS and servers, DVRs/surveillance systems, transportation and infrastructure, and emergency systems. It's typically integrated in the back office, server room, and data center environment. The rackmount / tower convertible design gives it enhanced flexibility for installation and operation in almost any environment.
By manually setting the UPS to ECO Mode, the UPS automatically detects the input power quality and discerns whether it should operate in Line Mode or ECO Mode. Under poor power conditions, the UPS will run in Line Mode, which guarantees the highest level of protection and the best possible power quality. When the input power quality is acceptable, the UPS switches to ECO Mode, which increases the total output power efficiency by up to 95%.
By manually setting the UPS to ECO Mode, the UPS automatically detects the input power quality and discerns whether it should operate in Line Mode or ECO Mode. Under poor power conditions, the UPS will run in Line Mode, which guarantees the highest level of protection and the best possible power quality. When the input power quality is acceptable, the UPS switches to ECO Mode, which increases the total output power efficiency by up to 95%.
| Features | |
| UPS topology The two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances. | Double-conversion (Online) |
| Output power capacity The maximum power that the device can produce. | 10000 VA |
| Output power The power that the device can produce. | 9000 W |
| Waveform | Pure sine |
| Input operation voltage (min) The minumum voltage needed by the device during operation. | 180 V |
| Input operation voltage (max) The maximum input voltage supported by the device. | 280 V |
| Input frequency The frequency (Hz) which is required to power the product. | 50/60 Hz |
| Output operation voltage (min) The minumum voltage produced by the device during operation. | 200 V |
| Output operation voltage (max) The maximum output voltage produced by the device. | 240 V |
| Maximum current The greatest possible amount of current, which is a quantity representing the rate of flow of electric charge. | 50 A |
| Surge energy rating A surge protector is an appliance designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. The surge energy rating is a measure of how much energy a surge protector can theoretically absorb in a single event, without failure. | 2430 J |
| Efficiency | 95% |
| Input power factor | 0.99 |
| Output power factor | 0.9 |
| Power Factor Correction (PFC) type | Active |
| Crest factor | 3:1 |
| Total Harmonic Distortion (THD) (linear load) | 3% |
| Total Harmonic Distortion (THD) (non-linear load) | 5% |
| EMI/RFI noise filtering |
|
| Noise level The amplitude level of the undesired background noise, usually measured in decibels (db). | 65 dB |
| Surge protection |
|
| Power protection features Features that protect the device against power problems e.g. overload. | Overload,Short circuit |
| Audible alarm(s) Alarms that make a sound when they are activated (set off). |
|
| Audible alarm modes | Alarm when on battery,Fault,Low battery alarm,Overload alarm |
| Ports & interfaces | |
| AC outlet types The type of outlet for AC electricity. | C13 coupler,C19 coupler,Terminal |
| Power plug A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection. | Terminal |
| AC outlets quantity The number of sockets in the device where AC electrical power can be connected. | 11 AC outlet(s) |
| USB port The device features a socket into which a USB cable can be plugged. |
|
| USB 2.0 ports quantity Number of USB 2.0 ports (connecting interfaces) in the device. USB 2.0 was released in April 2000 (now called "Hi-Speed"), adding higher maximum signaling rate of 480 Mbit/s (effective throughput up to 35 MB/s or 280 Mbit/s), USB 2.0 ports are usually black. | 1 |
| Serial interface |
|
| Serial interface type | RS-232 |
| Ethernet LAN (RJ-45) ports Number of Ethernet LAN (RJ-45) ports (connecting interfaces) in the device. Ethernet LAN (RJ-45) ports allow a computer to connect to the ethernet. | 2 |
| Emergency Power Off (EPO) connector |
|
| Battery | |
| Battery technology The type of battery in the device, e.g. nickel–cadmium (NiCd). | Sealed Lead Acid (VRLA) |
| Battery capacity The amount of electric charge a battery can deliver at the rated voltage. The more electrode material contained in the cell the greater its capacity. A small cell has less capacity than a larger cell with the same chemistry, although they develop the same open-circuit voltage. Capacity is measured in units such as amp-hour (A·h). | 9 Ah |
| Battery voltage The voltage (V) of the battery. | 12 V |
| Number of batteries supported The number of batteries that can be used with the product. | 2 |
| Typical backup time at full load The amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is fully loaded (100% of capacity). | 4 min |
| Typical backup time at half load The amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity). | 11 min |
| Battery recharge time Approximate time required to recharge the battery from completely empty to completely full | 5 h |
| Hot-swap battery |
|
| Replacement battery cartridge | RBP0072 |
| Design | |
| Form factor The shape or design of the product. | Rackmount/Tower |
| Housing material What the casing of the product is made of. | Metal |
| Rack capacity The spase that device fill in rack. | 6U |
| Product colour The colour e.g. red, blue, green, black, white. | Black |
| Display The description of display that can includes display type, resolution, size etc. | LCD |
| Energy Star certified This indicates that the product is compliant with Energy Star, which is an international standard for energy-efficient consumer products. |
|
| RoHS compliance The Restriction of Hazardous Substances (RoHS) Directive aims to restrict certain dangerous substances commonly used in electrical and electronic equipment. Any RoHS compliant product is tested for the presence of Lead (Pb), Cadmium (Cd), Mercury (Hg), Hexavalent chromium (Hex-Cr), Polybrominated biphenyls (PBB), and Polybrominated diphenyl ethers (PBDE). PBB and PBDE are flame retardants used in several plastics. For Cadmium and Hexavalent chromium, there must be less than 0.01% of the substance by weight at raw homogeneous materials level. For Lead, PBB, and PBDE, there must be no more than 0.1% of the material, when calculated by weight at raw homogeneous materials. Any RoHS compliant component must have 100 ppm or less of mercury and the mercury must not have been intentionally added to the component. In the EU, some military and medical equipment are exempt from RoHS compliance. |
|
| Certification | CE , C-Tick |
| Operational conditions | |
| Operating temperature (T-T) The minimum and maximum temperatures at which the product can be safely operated. | 0 - 40 °C |
| Storage temperature (T-T) The minimum and maximum temperatures at which the product can be safely stored. | -15 - 45 °C |
| Operating relative humidity (H-H) | 0 - 90% |
| Storage relative humidity (H-H) | 0 - 95% |
| Operating altitude | 0 - 3000 m |
| Non-operating altitude | 0 - 15000 m |
| Weight & dimensions | |
| Width The measurement or extent of something from side to side. | 433 mm |
| Depth The distance from the front to the back of something. | 820 mm |
| Height The measurement of the product from head to foot or from base to top. | 264 mm |
| Weight Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies. | 106.5 kg |
| Packaging data | |
| Rack mount kit |
|
| Package width The distance from one side of the packaging to the other. | 600 mm |
| Package depth The distance from the front to the back of the packaging. | 1115 mm |
| Package height The distance from the top to the bottom of the packaging. | 640 mm |
| Package weight Weight of the packaged product. | 133 kg |
| Other features | |
| Bypass | Automatic Bypass , Manual Bypass |
| SKU | 345583 |
| MPN | OL10000ERT3UP |
| Brand | Cyberpower |
| Product Condition | Brand New/Unused |
| Product Use | General |