Skip to content

CyberPower Professional Rackmount/Tower 3000VA/3000W 2U Line-interactive UPS

Item No:
347697
MPN:
PR3000ERTXL2U
$2,159.00

CyberPower Professional Rackmount/Tower 3000VA/3000W 2U Line-interactive UPS

$2,159.00
Payment options
Shipping Information
  • Available for shipping
  • Usually leaves our partner warehouse in 2-4 business days
Store Availability
  • 3-5 business days at Bankstown Store
  • 3-5 business days at Castle Hill Store
  • 2-4 business days at Northmead Store
Shipping Estimate
CyberPower PRO Rack/Tower LCD 3000VA / 3000W 2U Line Interactive UPS - 4* 12V/9AH - 9x IEC 320 C13, 1x IEC 320 C19 - 3 Yrs Adv. Replacement WTY 2 Yrs on int Batteries - Incl Rail kit
  • UPS Topology: Line-interactive
  • Active PFC Compatible
  • Input Connector Type: IEC C20, Outlet Connector Type: IEC C13 (x6), IEC C19 (x2)
  • Input Frequency: 50 ± 3/60 ± 3, Output Frequency: 50 ± 1%/60 ± 1%
  • Automatic Voltage Regulation: Double Boost, Single Buck

CyberPower PR3000ERTXL2U  with rackmount design guarantees power backup protection for home theatre systems, multimedia devices, IT equipment, computers, workstations, NAS/Storage devices, telecom devices, networking devices, and surveillance systems. The UPS adopts line-interactive topology with Automatic Voltage Regulation (AVR) function and offers stabilized Pure Sine Wave output to ensure high power quality. UPS’s output power factor is 1, which means it is capable of connecting to more critical loads than conventional UPS. It also features Battery Management Technology to help batteries obtain optimal life span by balancing battery string voltage.

Features
UPS topology The two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances. Line-Interactive
Output power capacity The maximum power that the device can produce. 3000 VA
Output power The power that the device can produce. 3000 W
Input operation voltage (min) The minumum voltage needed by the device during operation. 159 V
Input operation voltage (max) The maximum input voltage supported by the device. 288 V
Input frequency The frequency (Hz) which is required to power the product. 50/60 Hz
Output operation voltage (min) The minumum voltage produced by the device during operation. 220 V
Output operation voltage (max) The maximum output voltage produced by the device. 240 V
Automatic Voltage Regulation (AVR)
Surge energy rating A surge protector is an appliance designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. The surge energy rating is a measure of how much energy a surge protector can theoretically absorb in a single event, without failure. 2430 J
Transfer time (Line Mode to Battery Mode) 4 ms
Number of input phases 1
Power factor 1
Power Factor Correction (PFC) type Active
EMI/RFI noise filtering
Power protection features Features that protect the device against power problems e.g. overload. Overload,Short circuit
Audible alarm(s) Alarms that make a sound when they are activated (set off).
Web-based management Using a website/web application to manage something.
Management protocols SNMP/HTTP
Audible alarm modes Alarm when on battery,Low battery alarm,Overload alarm
Socket circuit breaker
Ports & interfaces
AC outlet types The type of outlet for AC electricity. C13 coupler,C19 coupler
Power plug A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection. C20 coupler
AC outlets quantity The number of sockets in the device where AC electrical power can be connected. 8 AC outlet(s)
USB port The device features a socket into which a USB cable can be plugged.
Serial interface
Serial interface type RS-232
Ethernet LAN (RJ-45) ports Number of Ethernet LAN (RJ-45) ports (connecting interfaces) in the device. Ethernet LAN (RJ-45) ports allow a computer to connect to the ethernet. 2
Emergency Power Off (EPO) connector
Battery
Battery technology The type of battery in the device, e.g. nickel–cadmium (NiCd). Sealed Lead Acid (VRLA)
Number of batteries supported The number of batteries that can be used with the product. 1
Typical backup time at full load The amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is fully loaded (100% of capacity). 1.7 min
Typical backup time at half load The amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity). 7.1 min
Battery recharge time Approximate time required to recharge the battery from completely empty to completely full 3 h
Hot-swap battery
Replacement battery cartridge RBP0129
Design
Form factor The shape or design of the product. Rackmount/Tower
Housing material What the casing of the product is made of. Metal
Rack capacity The spase that device fill in rack. 2U
Cable length How long the cable is. 2.4 m
Product colour The colour e.g. red, blue, green, black, white. Black
Display The description of display that can includes display type, resolution, size etc. LCD
Energy Star certified This indicates that the product is compliant with Energy Star, which is an international standard for energy-efficient consumer products.
RoHS compliance The Restriction of Hazardous Substances (RoHS) Directive aims to restrict certain dangerous substances commonly used in electrical and electronic equipment. Any RoHS compliant product is tested for the presence of Lead (Pb), Cadmium (Cd), Mercury (Hg), Hexavalent chromium (Hex-Cr), Polybrominated biphenyls (PBB), and Polybrominated diphenyl ethers (PBDE). PBB and PBDE are flame retardants used in several plastics. For Cadmium and Hexavalent chromium, there must be less than 0.01% of the substance by weight at raw homogeneous materials level. For Lead, PBB, and PBDE, there must be no more than 0.1% of the material, when calculated by weight at raw homogeneous materials. Any RoHS compliant component must have 100 ppm or less of mercury and the mercury must not have been intentionally added to the component. In the EU, some military and medical equipment are exempt from RoHS compliance.
Certification CE , FCC Class A , UL , CISPR 22 Class A , IEC62040-2 , RCM , VCCI , EN 61000-3-2
Operational conditions
Operating temperature (T-T) The minimum and maximum temperatures at which the product can be safely operated. 0 - 40 °C
Storage temperature (T-T) The minimum and maximum temperatures at which the product can be safely stored. -15 - 45 °C
Operating relative humidity (H-H) 0 - 95%
Storage relative humidity (H-H) 0 - 95%
Operating altitude 0 - 3000 m
Non-operating altitude 0 - 15000 m
Weight & dimensions
Width The measurement or extent of something from side to side. 433 mm
Depth The distance from the front to the back of something. 500 mm
Height The measurement of the product from head to foot or from base to top. 86.5 mm
Weight Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies. 32.8 kg
Packaging data
Package width The distance from one side of the packaging to the other. 560 mm
Package depth The distance from the front to the back of the packaging. 620 mm
Package height The distance from the top to the bottom of the packaging. 275 mm
Package volume 40800 cm³
Other features
Bypass GreenPower UPS
More Information
SKU 347697
MPN PR3000ERTXL2U
Brand Cyberpower
Product Condition Brand New/Unused
Stock Availability Available for Shipping
Warranty Period 3 Years Warranty
Warranty Contact https://www.cyberpowersystems.com/