CyberPower Switched 0U Black 24 AC Outlet(s) 30A PDU

Item No:
461597
MPN:
PDU30SWVHVT24FNET
$1,301.87
Payment options

This product is currently not available!

Shipping Information
  • Unavailable for shipping
  • This product is not currently available for purchase
Store Availability
  • Unavailable at Bankstown Store
  • Unavailable at Castle Hill Store
  • Unavailable at Northmead Store
CyberPower PDU30SWVHVT24FNET, Switched, 0U, Vertical, Black, LCD, 24 AC outlet(s)
The CyberPower (PDU30SWVHVT24FNET) 16-outlet 0U rack mount switched power distribution unit (PDU) provides 200-240V 30A output. It distributes power to IEC-320 C13 (21) / C19 (3) receptacles from a single NEMA L6-30P plug, with unfiltered electrical pass-through. The switched outlet receptacles can be managed individually or collectively over the network using CyberPower Management Console /web browser and the RJ45 Ethernet port for network connection or locally using the LCD controls. Outlets can be turned on, turned off, or recycled on demand or at programmed times to address a number of needs including remote rebooting of locked equipment, load shedding, power sequencing, and locking out unauthorized loads.

The front LCD panel provides local control and monitoring of the PDU. Using the LCD controls, outlets can be used to turn on or turn off a single receptacle or multiple receptacles. Load management is accomplished by using the display to measure the electrical current used by connected equipment in amps. The LCD can also display input voltages to assist in diagnosing potential issues with input power. Power being consumed in watts can also be displayed, as well as, the IP address of the network interface for ease of installation.

The CyberPower Management Console offers real-time remote monitoring of PDU vitals as well as controlling outlets for networked clients. You can program outlets to turn on, turn off, or recycle at specified times. In addition to control, you can use Event Logging via a web browser/network connection to review history on power conditions, such as input voltages, load levels, and outlet status. Automatic event notifications via Email or SNMP Trap are sent to designated user when specified power events occur.

Designed for datacenters and other electrically demanding applications, this unit has a rugged, industrial-grade metal housing and a 10-foot AC power cord. A RJ-45 port enables the connection of the optional ENVIROSENSOR environmental sensor for monitoring the heat and humidity in an IT center. It can be mounted horizontally, includes cord retention trays and is UL60950_1 and FCC Class A certified. A three-year warranty ensures that this PDU is free of defects in design, assembly, material or workmanship.
Design
PDU types A power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing, and remote monitoring and control by LAN or SNMP. Switched
Rack capacity The spase that device fill in rack. 0U
Mounting What size the mounting head of the product is, to couple it with a camera. Vertical
Product colour The colour e.g. red, blue, green, black, white. Black
Display The description of display that can includes display type, resolution, size etc. LCD
Ports & interfaces
AC outlets quantity The number of sockets in the device where AC electrical power can be connected. 24 AC outlet(s)
Power plug A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection. NEMA L6-30P
Serial ports quantity The number of serial ports in a computer or peripheral. A serial port is a serial communication physical interface through which information transfers in or out one bit at a time. The term "serial port" usually identifies hardware more or less compliant to the RS-232 standard, intended to interface with a modem or with a similar communication device. In modern computers and peripherals, serial ports have largely been replaced by USBs and other interfaces. 1
Ethernet LAN (RJ-45) ports Number of Ethernet LAN (RJ-45) ports (connecting interfaces) in the device. Ethernet LAN (RJ-45) ports allow a computer to connect to the ethernet. 1
Output connections 21 x IEC-320 C13 & 3 x C19
Features
LED indicators
Cable length How long the cable is. 3 m
RoHS compliance The Restriction of Hazardous Substances (RoHS) Directive aims to restrict certain dangerous substances commonly used in electrical and electronic equipment. Any RoHS compliant product is tested for the presence of Lead (Pb), Cadmium (Cd), Mercury (Hg), Hexavalent chromium (Hex-Cr), Polybrominated biphenyls (PBB), and Polybrominated diphenyl ethers (PBDE). PBB and PBDE are flame retardants used in several plastics. For Cadmium and Hexavalent chromium, there must be less than 0.01% of the substance by weight at raw homogeneous materials level. For Lead, PBB, and PBDE, there must be no more than 0.1% of the material, when calculated by weight at raw homogeneous materials. Any RoHS compliant component must have 100 ppm or less of mercury and the mercury must not have been intentionally added to the component. In the EU, some military and medical equipment are exempt from RoHS compliance.
Certification UL60950_1, CSA C22.2, FCC Class A
Management features
Management platform SNMP, HTTP
Power
Nominal input voltage The voltage which the manufacturer recommends that the device needs to operate normally. 200-240 V
AC input frequency 50 - 60 Hz
Maximum current The greatest possible amount of current, which is a quantity representing the rate of flow of electric charge. 30 A
Nominal output voltage The voltage which the manufacturer states that the device can produce. 200-240 V
Maximum input current per phase 30 A
Power protection features Features that protect the device against power problems e.g. overload. Overload
Weight & dimensions
Dimensions (WxDxH) Dimensions of the product (Width x Depth x Height). 1778 x 44.45 x 55.88 mm
Weight Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies. 6.89 kg
Operational conditions
Operating temperature (T-T) The minimum and maximum temperatures at which the product can be safely operated. 0 - 45 °C
Storage temperature (T-T) The minimum and maximum temperatures at which the product can be safely stored. -15 - 45 °C
Operating relative humidity (H-H) 0 - 95%
Operating altitude 0 - 4500 m
Non-operating altitude 0 - 15000 m
More Information
SKU 461597
MPN PDU30SWVHVT24FNET
Brand Cyberpower
Product Condition Brand New/Unused
Stock Availability Available for Shipping
Product Use General
Warranty Period 3 Years Warranty
Warranty Contact https://www.cyberpowersystems.com/