Skip to content

Cyberpower PFC Sinewave Series 1350VA UPS

Item No:
774953
MPN:
CP1350EPFCLCD
$579.00

Cyberpower PFC Sinewave Series 1350VA UPS

$579.00
Payment options
Shipping Information
  • Available for shipping
  • Usually leaves our partner warehouse in 2-4 business days
Store Availability
  • 3-5 business days at Bankstown Store
  • 3-5 business days at Castle Hill Store
  • 2-4 business days at Northmead Store
Shipping Estimate
CyberPower CP1350EPFCLCD, Line-Interactive, 1.35 kVA, 780 W, Sine, 165 V, 265 V
Backup PFC Sinewave Series for Mac.

Designed for new Mac Pro with additional USB ports on front to recharge mobile equipments.
Features
UPS topology The two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances. Line-Interactive
Output power capacity The maximum power that the device can produce. 1.35 kVA
Output power The power that the device can produce. 780 W
Waveform Sine
Input operation voltage (min) The minumum voltage needed by the device during operation. 165 V
Input operation voltage (max) The maximum input voltage supported by the device. 265 V
Input frequency The frequency (Hz) which is required to power the product. 50/60 Hz
Output frequency 50/60 Hz
Automatic Voltage Regulation (AVR)
Efficiency 98.5%
EMI/RFI noise filtering
Noise level The amplitude level of the undesired background noise, usually measured in decibels (db). 35 dB
Surge protection
Surge protection features Digital Subscriber Line (DSL), Fax, Modem, Network, Telephone
Power protection features Features that protect the device against power problems e.g. overload. Overload
Audible alarm(s) Alarms that make a sound when they are activated (set off).
Audible alarm modes Alarm when on battery, Fault, Low battery alarm, Overload alarm
Auto-restart
Ports & interfaces
Power plug A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection. C14 coupler
AC outlets quantity The number of sockets in the device where AC electrical power can be connected. 6 AC outlet(s)
Number of type F outputs 6
USB port The device features a socket into which a USB cable can be plugged.
USB 2.0 ports quantity Number of USB 2.0 ports (connecting interfaces) in the device. USB 2.0 was released in April 2000 (now called "Hi-Speed"), adding higher maximum signaling rate of 480 Mbit/s (effective throughput up to 35 MB/s or 280 Mbit/s), USB 2.0 ports are usually black. 3
Serial interface
Serial ports quantity The number of serial ports in a computer or peripheral. A serial port is a serial communication physical interface through which information transfers in or out one bit at a time. The term "serial port" usually identifies hardware more or less compliant to the RS-232 standard, intended to interface with a modem or with a similar communication device. In modern computers and peripherals, serial ports have largely been replaced by USBs and other interfaces. 1
Modem (RJ-11) ports 1
Ethernet LAN (RJ-45) ports Number of Ethernet LAN (RJ-45) ports (connecting interfaces) in the device. Ethernet LAN (RJ-45) ports allow a computer to connect to the ethernet. 1
Cabling technology Type of cable technology performance. 10/100/1000Base-T(X)
Battery
Battery capacity The amount of electric charge a battery can deliver at the rated voltage. The more electrode material contained in the cell the greater its capacity. A small cell has less capacity than a larger cell with the same chemistry, although they develop the same open-circuit voltage. Capacity is measured in units such as amp-hour (A·h). 8.5 Ah
Battery voltage The voltage (V) of the battery. 12 V
Number of batteries supported The number of batteries that can be used with the product. 2
Typical backup time at full load The amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is fully loaded (100% of capacity). 4 min
Typical backup time at half load The amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity). 10 min
Battery recharge time Approximate time required to recharge the battery from completely empty to completely full 8 h
Design
Form factor The shape or design of the product. Tower
Cooling type The method used to cool the device or to cool the air around the device. Passive
Product colour The colour e.g. red, blue, green, black, white. Black
Display type Type of display (screen) e.g. LCD. LCD
LED indicators
Technical details
Sustainability certificates RoHS
Weight & dimensions
Width The measurement or extent of something from side to side. 100 mm
Depth The distance from the front to the back of something. 370 mm
Height The measurement of the product from head to foot or from base to top. 265 mm
Weight Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies. 10.9 kg
Other features
Nominal output voltage The voltage which the manufacturer states that the device can produce. 230 V
More Information
SKU 774953
MPN CP1350EPFCLCD
Brand Cyberpower
Product Condition Brand New/Unused
Stock Availability Available for Shipping
Product Use General
Warranty Period 2 Years Warranty
Warranty Contact https://www.cyberpowersystems.com/