Cisco IE-2000U-16TC-G, Managed, L2/L4, Fast Ethernet (10/100), Full duplex
The Cisco Industrial Ethernet (IE) 2000U Switches are compact switches for the harsh, rugged environments often found in the energy and utility industries. IE 2000U switches support the communications needs of the utility- and customer-owned energy-delivery infrastructure across distributed generation, transmission, and distribution sectors. This infrastructure includes substation applications supporting electrical transmission and distribution, renewable generation, oil and gas, water, distributed generation, cogeneration, and trackside operations.
| Management features | |
| Switch type What switch device has, managed or unmanaged. | Managed |
| Switch layer A network switch is a computer networking device that links networking segments. A switch has different layers, such as layer 2 (a network bridge, operating at the data link layer, interconnecting a small number of devices) and layer 4 (can act as a firewall, amongst other things). | L2/L4 |
| Quality of Service (QoS) support |
|
| Web-based management Using a website/web application to manage something. |
|
| ARP inspection |
|
| Ports & interfaces | |
| Basic switching RJ-45 Ethernet ports quantity The number of basic switching RJ-45 Ethernet ports (sockets). | 16 |
| Basic switching RJ-45 Ethernet ports type The type/category of basic switching RJ-45 Ethernet ports (sockets). | Fast Ethernet (10/100) |
| Fast Ethernet (copper) ports quantity | 16 |
| Combo SFP ports quantity | 2 |
| Compatible memory cards Types of memory cards which can be used with this product. | SD |
| Network | |
| Networking standards The way in which the network is working, e.g. IEEE 802.11a, IEEE 802.11b, IEEE 802.11g. | IEEE 802.1D,IEEE 802.1Q,IEEE 802.1ag,IEEE 802.1p,IEEE 802.1s,IEEE 802.1w,IEEE 802.1x,IEEE 802.3,IEEE 802.3ab,IEEE 802.3ad,IEEE 802.3af,IEEE 802.3ah,IEEE 802.3at,IEEE 802.3u,IEEE 802.3x,IEEE 802.3z |
| 10G support The product can use Oracle 10G, which is a database management system introduced in 2003. |
|
| Full duplex A full-duplex system allows communication in both directions, and unlike half-duplex, allows this to happen simultaneously. |
|
| Link aggregation |
|
| Broadcast storm control |
|
| Spanning tree protocol |
|
| MAC address auto-learning supported |
|
| MAC address auto-aging supported |
|
| VLAN support A Virtual Local Area Network (VLAN) consists of a group of computers and switches that can be physically distributed over different networks and buildings, but form one LAN on a logical level. |
|
| Virtual LAN features | Private VLAN |
| Number of VLANs | 1005 |
| Data transmission | |
| Switching capacity The data transfer capacity of the switch per second. | 7.6 Gbit/s |
| Forwarding rate | 5.66 Mpps |
| MAC address table The MAC address is the 'Media Access Control Address'. It is a unique address given to a network interface controller (NIC) in a device. A MAC address table shows the addresses in a table format. | 8000 entries |
| Security | |
| DHCP features | DHCP snooping |
| Access Control List (ACL) |
|
| IGMP entries | 1000 |
| Security algorithms Security algorithms are used to provide authentication, cipher key generation, integrity and radio link privacy to users on mobile networks. The security algorithms supported are the ones that can be used with this product. | SNMPv3,SSH,SSL/TLS |
| SSH/SSL support |
|
| Authentication | MAC-based authentication, Web-based authentication |
| Multicast features | |
| Multicast support |
|
| Protocols | |
| Routing protocols | BGP4,EIGRP,HSRP,IS-IS,OSPF |
| Design | |
| Product colour The colour e.g. red, blue, green, black, white. | Black |
| International Protection (IP) code The IP code classifies and rates the degree of protection provided against the intrusion (including body parts such as hands and fingers), dust, accidental contact, and water by mechanical casings and electrical enclosures. It is published by the International Electrotechnical Commission (IEC). The digits (characteristic numerals) indicate conformity with the conditions summarized in the tables below. Where there is no protection rating with regard to one of the criteria, the digit is replaced with the letter X. an electrical socket rated IP22 is protected against insertion of fingers and will not be damaged or become unsafe during a specified test in which it is exposed to vertically or nearly vertically dripping water. Another example is the Sony Xperia Z Ultra, one of the first cellular phones to be IP-rated; it is rated at IP58 and marketed as "dust resistant" and can be "immersed in 1.5 meter of freshwater for up to 30 minutes". | IP30 |
| DIN rail mounting |
|
| Safety List of regulatory safety standards for all countries in which this product has been certified. | UL508, CSA C22.2 No. 142, UL 60950-1, CSA 60950-1, EN 60950-1, IEC 60950-1 |
| Electromagnetic compatibility List of countries and their respective regulatory agency standards with which the product complies. | EN 55024 (CISPR 24), AS/NZS CISPR 24, KN 24, IEC61000-4-2 (Criteria A - Class 2), IEC61000-4-3/ENV50204 (Criteria A), IEC61000-4-4 (Criteria A/Criteria B), IEC61000-4-5 (Criteria B), IEC61000-4-6 (Criteria A), FCC Part 15 Class A, EN 55022 Class A(CISPR22 Class A), ICES-003 Class A, EN 300 386, VCCI Class A, AS/NZS CISPR22 Class A, CNS 13438 Class A, KN 22 Class A CE Marking |
| Performance | |
| Memory type Type of memory in the device e.g. DDR3, SRAM (Static RAM). | DRAM |
| Internal memory The amount of memory, usually measured in bytes (e.g. MB, GB), which is installed in the system's hardware. | 256 MB |
| Flash memory | 1024 MB |
| Mean time between failures (MTBF) Statistical model used to indicate product/mechanism reliability; expressed in hours and percentage of duty cycle. This number (in hours) does not indicate the mean time before failure for a single unit/mechanism. | 535190 h |
| Power | |
| Redundant power supply (RPS) support Additional power supply which can run a computer if the main power supply fails. |
|
| Power consumption (typical) Amount of power consumed by this model, often expressed in watts (W). Typical values that manufacturers give are power consumption when off, standby/suspended mode, typical use, maximum usage. | 13 W |
| Power consumption (max) The maximum amount of power used by the device. | 20 W |
| Power over Ethernet (PoE) | |
| Power over Ethernet (PoE) The device supports Power over Ethernet (PoE), which is one of several standardized or ad-hoc systems which pass electrical power along with data on Ethernet cabling. This allows a single cable to provide both data connection and electrical power to devices such as wireless access points or IP cameras. |
|
| Operational conditions | |
| Operating temperature (T-T) The minimum and maximum temperatures at which the product can be safely operated. | -40 - 75 °C |
| Storage temperature (T-T) The minimum and maximum temperatures at which the product can be safely stored. | -50 - 85 °C |
| Operating relative humidity (H-H) | 5 - 95% |
| Operating altitude | -60 - 3000 m |
| Non-operating altitude | 0 - 4600 m |
| Weight & dimensions | |
| Width The measurement or extent of something from side to side. | 127 mm |
| Depth The distance from the front to the back of something. | 134 mm |
| Height The measurement of the product from head to foot or from base to top. | 130 mm |
| Weight Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies. | 1.97 kg |
| SKU | 457211 |
| MPN | IE-2000U-16TC-G |
| Brand | Cisco |
| Product Condition | Brand New/Unused |
| Product Use | General |