Shipping Information
- Available for shipping
- Usually leaves our partner warehouse in 2-4 business days
Store Availability
- 3-5 business days at Bankstown Store
- 3-5 business days at Castle Hill Store
- 2-4 business days at Northmead Store
Shipping Estimate
ATEN PE6108, Monitored, 1U, Horizontal, Metal, Black, 8 AC outlet(s)
The PE6108 eco PDU is intelligent PDUs that contains 8 AC outlets and is available in various IEC or NEMA socket configurations. It provides secure, centralized, intelligent, power management (power on, off, cycle) of data center IT equipment (servers, storage systems, KVM switches, network devices, serial data devices, etc.), as well as the ability to monitor the center's health environment via sensors*.
The eco PDUs offer remote power control combined with real-time power measurement - allowing you to control and monitor the power status of devices attached to the PDUs at the PDU device level from practically any location via a TCP/IP connection.
The eco PDU supports any 3rd party v3 SNMP Manager Software and the eco DC (Energy Management Web GUI). The eco DC provides you with an easy method for managing multiple devices, offering an intuitive and user-friendly Graphical User Interface that allows you to configure a PDU device and monitor power status of the equipment connected to it. With the eco DC, the Sensor-enabled eco PDU also offers comprehensive power analysis reports which can separate by departments and locations, providing precise measurements of current, voltage, power and watt-hour in a real-time display.
With its advanced security features and ease of operation, the eco PDU is the most convenient, most reliable, and most cost effective way to remotely manage power access for multiple computer installations and allocate power resources in the most efficient way possible.
Note: Sensors are optional accessories. A sensor-enabled installation is required to generate a more complete energy-efficient data and chart. Higher sensor installation density is helpful to generate more accurate data.
Power Distribution
- Space saving 1U rack mount design with rear mounting
- IEC or NEMA outlet models
- 3 digit 7-segment front panel LED shows Current / IP Address
- Remote users can monitor outlet status via web pages on their browsers
- Safe shutdown support
- Separate power for the unit's own power and its power outlets. The user interface is still accessible even when an overload condition trips the devices' circuit breaker
Remote Access
- Remote power control via TCP/IP and a built in 10/100 Ethernet port
- Network Interfaces: TCP/IP, UDP, HTTP, HTTPS, SSL, SMTP, DHCP, NTP, DNS, 10Base-T/100Base-TX, auto sense, Ping
- eco PDU Power Management software
The eco PDUs offer remote power control combined with real-time power measurement - allowing you to control and monitor the power status of devices attached to the PDUs at the PDU device level from practically any location via a TCP/IP connection.
The eco PDU supports any 3rd party v3 SNMP Manager Software and the eco DC (Energy Management Web GUI). The eco DC provides you with an easy method for managing multiple devices, offering an intuitive and user-friendly Graphical User Interface that allows you to configure a PDU device and monitor power status of the equipment connected to it. With the eco DC, the Sensor-enabled eco PDU also offers comprehensive power analysis reports which can separate by departments and locations, providing precise measurements of current, voltage, power and watt-hour in a real-time display.
With its advanced security features and ease of operation, the eco PDU is the most convenient, most reliable, and most cost effective way to remotely manage power access for multiple computer installations and allocate power resources in the most efficient way possible.
Note: Sensors are optional accessories. A sensor-enabled installation is required to generate a more complete energy-efficient data and chart. Higher sensor installation density is helpful to generate more accurate data.
Power Distribution
- Space saving 1U rack mount design with rear mounting
- IEC or NEMA outlet models
- 3 digit 7-segment front panel LED shows Current / IP Address
- Remote users can monitor outlet status via web pages on their browsers
- Safe shutdown support
- Separate power for the unit's own power and its power outlets. The user interface is still accessible even when an overload condition trips the devices' circuit breaker
Remote Access
- Remote power control via TCP/IP and a built in 10/100 Ethernet port
- Network Interfaces: TCP/IP, UDP, HTTP, HTTPS, SSL, SMTP, DHCP, NTP, DNS, 10Base-T/100Base-TX, auto sense, Ping
- eco PDU Power Management software
| Design | |
| PDU types A power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing, and remote monitoring and control by LAN or SNMP. | Monitored |
| Rack capacity The spase that device fill in rack. | 1U |
| Mounting What size the mounting head of the product is, to couple it with a camera. | Horizontal |
| Housing material What the casing of the product is made of. | Metal |
| Product colour The colour e.g. red, blue, green, black, white. | Black |
| On/off switch The button which is pressed to switch the device on or off. |
|
| Ports & interfaces | |
| AC outlets quantity The number of sockets in the device where AC electrical power can be connected. | 8 AC outlet(s) |
| Power plug A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection. | C20 coupler |
| AC outlet types The type of outlet for AC electricity. | C13 coupler |
| Ethernet LAN (RJ-45) ports Number of Ethernet LAN (RJ-45) ports (connecting interfaces) in the device. Ethernet LAN (RJ-45) ports allow a computer to connect to the ethernet. | 1 |
| Features | |
| LED indicators | LAN, Link, Power, Status |
| Cable length How long the cable is. | 3 m |
| Management features | |
| Monitoring | Current |
| Power | |
| Nominal input voltage The voltage which the manufacturer recommends that the device needs to operate normally. | 100-240 V |
| AC input frequency | 50/60 Hz |
| Maximum current The greatest possible amount of current, which is a quantity representing the rate of flow of electric charge. | 10 A |
| Nominal output voltage The voltage which the manufacturer states that the device can produce. | 100-240 V |
| Load capacity | 2300 VA |
| Maximum input current per phase | 10 A |
| Certificates | |
| Compliance certificates | RoHS |
| Operational conditions | |
| Operating temperature (T-T) The minimum and maximum temperatures at which the product can be safely operated. | 0 - 50 °C |
| Storage temperature (T-T) The minimum and maximum temperatures at which the product can be safely stored. | -20 - 60 °C |
| Operating relative humidity (H-H) | 0 - 80% |
| Storage relative humidity (H-H) | 0 - 80% |
| Weight & dimensions | |
| Width The measurement or extent of something from side to side. | 220.4 mm |
| Depth The distance from the front to the back of something. | 432.4 mm |
| Height The measurement of the product from head to foot or from base to top. | 44 mm |
| Weight Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies. | 2.77 kg |
| SKU | 821179 |
| MPN | PE6108G-ATB-G |
| Brand | ATEN |
| Product Condition | Brand New/Unused |
| Stock Availability | Available for Shipping |
| Product Use | General |
| Warranty Period | 2 Years Warranty |
| Warranty Contact | https://www.aten.com/ |