APC SRV2KRI, Double-conversion (Online), 2 kVA, 1600 W, Sine, 160 V, 280 V
Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS power overload or fault.
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
ECO Mode
Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection.
Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
LCD display
Alpha-Numeric Display which displays system parameters and alarms.
Serial connectivity
Provides management of the UPS via a serial port.
USB connectivity
Provides management of the UPS via a USB port (not available on all models).
Features
Management Software
Allows you to easily monitor your utility power and manage your UPS.
ECO Mode
Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection.
Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
High efficiency
High efficiency rates that remain stable even at lower operating power levels.
SmartSlot
Customize UPS capabilities with management cards.
Intuitive LCD interface
Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.
Double conversion on-line topology
Guarantees a consistently high level of power quality. Any disturbances on the distribution waveform are regenerated via the zero transfer time AC to DC then DC to AC conversion process. The battery is only used as a back-up source.
Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.
Wide input voltage range
Designed for harsh electrical environments to save battery life.
Serviceability
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Audible alarms
Provides notification of changing utility power and UPS power conditions.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Predicitive failure notification
Provides early-warning fault analysis ensuring proactive component replacement.
Manageability
Serial connectivity
Provides management of the UPS via a serial port.
SmartSlot
Customize UPS capabilities with management cards.
LCD graphics display
Text and mimic diagrams that display modes of operation, system parameters and alarms.
Network manageable
Provides remote power management of the UPS over the network.
LED Indicators
Provide easy-to-read status of the unit and utility power conditions.
Availability
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Supplies utility power to the connected loads in the event of a UPS power overload or fault.
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
ECO Mode
Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection.
Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
LCD display
Alpha-Numeric Display which displays system parameters and alarms.
Serial connectivity
Provides management of the UPS via a serial port.
USB connectivity
Provides management of the UPS via a USB port (not available on all models).
Features
Management Software
Allows you to easily monitor your utility power and manage your UPS.
ECO Mode
Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection.
Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
High efficiency
High efficiency rates that remain stable even at lower operating power levels.
SmartSlot
Customize UPS capabilities with management cards.
Intuitive LCD interface
Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.
Double conversion on-line topology
Guarantees a consistently high level of power quality. Any disturbances on the distribution waveform are regenerated via the zero transfer time AC to DC then DC to AC conversion process. The battery is only used as a back-up source.
Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.
Wide input voltage range
Designed for harsh electrical environments to save battery life.
Serviceability
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Audible alarms
Provides notification of changing utility power and UPS power conditions.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Predicitive failure notification
Provides early-warning fault analysis ensuring proactive component replacement.
Manageability
Serial connectivity
Provides management of the UPS via a serial port.
SmartSlot
Customize UPS capabilities with management cards.
LCD graphics display
Text and mimic diagrams that display modes of operation, system parameters and alarms.
Network manageable
Provides remote power management of the UPS over the network.
LED Indicators
Provide easy-to-read status of the unit and utility power conditions.
Availability
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
| Features | |
| UPS topology The two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances. | Double-conversion (Online) |
| Output power capacity The maximum power that the device can produce. | 2 kVA |
| Output power The power that the device can produce. | 1600 W |
| Waveform | Sine |
| Input operation voltage (min) The minumum voltage needed by the device during operation. | 160 V |
| Input operation voltage (max) The maximum input voltage supported by the device. | 280 V |
| Input frequency The frequency (Hz) which is required to power the product. | 40/70 Hz |
| Output operation voltage (min) The minumum voltage produced by the device during operation. | 220 V |
| Output operation voltage (max) The maximum output voltage produced by the device. | 240 V |
| Output frequency | 50/60 Hz |
| Output voltage regulation | 1% |
| Surge energy rating A surge protector is an appliance designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. The surge energy rating is a measure of how much energy a surge protector can theoretically absorb in a single event, without failure. | 600 J |
| Number of input phases | 1 |
| Number of output phases | 1 |
| Efficiency | 88% |
| Input power factor | 0.95 |
| Output power factor | 0.8 |
| Crest factor | 3:1 |
| ECO mode |
|
| Emergency Power Off (EPO) |
|
| Output voltage Total Harmonic Distortion (THD) | 3% |
| Noise level The amplitude level of the undesired background noise, usually measured in decibels (db). | 50 dB |
| Audible alarm(s) Alarms that make a sound when they are activated (set off). |
|
| Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
| Auto-restart |
|
| Maintenance-free |
|
| Socket circuit breaker |
|
| Ports & interfaces | |
| AC outlet types The type of outlet for AC electricity. | C13 coupler |
| AC outlets quantity The number of sockets in the device where AC electrical power can be connected. | 4 AC outlet(s) |
| USB port The device features a socket into which a USB cable can be plugged. |
|
| USB port type | USB Type-B |
| Serial interface |
|
| Serial ports quantity The number of serial ports in a computer or peripheral. A serial port is a serial communication physical interface through which information transfers in or out one bit at a time. The term "serial port" usually identifies hardware more or less compliant to the RS-232 standard, intended to interface with a modem or with a similar communication device. In modern computers and peripherals, serial ports have largely been replaced by USBs and other interfaces. | 1 |
| SmartSlot |
|
| Battery | |
| Battery technology The type of battery in the device, e.g. nickel–cadmium (NiCd). | Sealed Lead Acid (VRLA) |
| Battery recharge time Approximate time required to recharge the battery from completely empty to completely full | 4 h |
| Automatic battery test |
|
| Design | |
| Form factor The shape or design of the product. | Rackmount |
| Rack capacity The spase that device fill in rack. | 2U |
| Product colour The colour e.g. red, blue, green, black, white. | Black |
| LED indicators |
|
| Display The description of display that can includes display type, resolution, size etc. | LCD |
| Certification | CE, IEC 62040-1-1, IEC 62040-1-2 REACH |
| Operational conditions | |
| Operating temperature (T-T) The minimum and maximum temperatures at which the product can be safely operated. | 0 - 40 °C |
| Storage temperature (T-T) The minimum and maximum temperatures at which the product can be safely stored. | -20 - 50 °C |
| Operating relative humidity (H-H) | 0 - 95% |
| Storage relative humidity (H-H) | 0 - 95% |
| Operating altitude | 0 - 3000 m |
| Technical details | |
| Sustainability certificates | RoHS |
| Weight & dimensions | |
| Width The measurement or extent of something from side to side. | 437 mm |
| Depth The distance from the front to the back of something. | 462 mm |
| Height The measurement of the product from head to foot or from base to top. | 86 mm |
| Weight Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies. | 18.2 kg |
| Packaging data | |
| Cables included | USB cable |
| Manual |
|
| Software CD |
|
| Package width The distance from one side of the packaging to the other. | 551 mm |
| Package depth The distance from the front to the back of the packaging. | 599 mm |
| Package height The distance from the top to the bottom of the packaging. | 142 mm |
| Package weight Weight of the packaged product. | 20.7 kg |
| Other features | |
| Nominal output voltage The voltage which the manufacturer states that the device can produce. | 230 V |
| Nominal input voltage The voltage which the manufacturer recommends that the device needs to operate normally. | 230 V |
| SKU | 540803 |
| MPN | SRV2KRI |
| Brand | APC |
| Product Condition | Brand New/Unused |
| Stock Availability | Available for Shipping |
| Product Use | General |
| Warranty Period | 2 Years Warranty |
| Warranty Contact | https://www.apc.com/ |