Skip to content

APC Switched Rack PDU Power Distribution Unit (PDU) 0U Black 24 AC outlet(s)

Item No:
458939
MPN:
AP8653
$3,076.87

APC Switched Rack PDU Power Distribution Unit (PDU) 0U Black 24 AC outlet(s)

$3,076.87
Payment options
Shipping Information
  • Available for shipping
  • Usually leaves our partner warehouse in 2-4 business days
Store Availability
  • 3-5 business days at Bankstown Store
  • 3-5 business days at Castle Hill Store
  • 2-4 business days at Northmead Store
Shipping Estimate
APC Switched Rack PDU, Metered,Switched, 0U, Single-phase, Vertical, Black, 24 AC outlet(s)
APC Switched Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and individual outlet power metering. Remote outlet level controls allow power on/off functionality for power recycling to reboot locked-up equipment and to avoid unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding. Current metering provides real-time remote monitoring of connected loads. Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, and locking IEC receptacles. User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by APC Centralized Management platforms using InfraStruxure Central, Capacity Manager and Change Manager.

Includes: CAN Port Terminator, Installation guide, Rack Mounting brackets, Safety guide, Sample locking IEC power cord, Serial configuration cable
Design
PDU types A power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing, and remote monitoring and control by LAN or SNMP. Metered,Switched
Type Characteristics of the device. Single-phase
Rack capacity The spase that device fill in rack. 0U
Mounting What size the mounting head of the product is, to couple it with a camera. Vertical
Product colour The colour e.g. red, blue, green, black, white. Black
Ports & interfaces
AC outlets quantity The number of sockets in the device where AC electrical power can be connected. 24 AC outlet(s)
Power plug A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection. IEC309
AC outlet types The type of outlet for AC electricity. C13 coupler,C19 coupler
Features
Cable length How long the cable is. 3 m
RoHS compliance The Restriction of Hazardous Substances (RoHS) Directive aims to restrict certain dangerous substances commonly used in electrical and electronic equipment. Any RoHS compliant product is tested for the presence of Lead (Pb), Cadmium (Cd), Mercury (Hg), Hexavalent chromium (Hex-Cr), Polybrominated biphenyls (PBB), and Polybrominated diphenyl ethers (PBDE). PBB and PBDE are flame retardants used in several plastics. For Cadmium and Hexavalent chromium, there must be less than 0.01% of the substance by weight at raw homogeneous materials level. For Lead, PBB, and PBDE, there must be no more than 0.1% of the material, when calculated by weight at raw homogeneous materials. Any RoHS compliant component must have 100 ppm or less of mercury and the mercury must not have been intentionally added to the component. In the EU, some military and medical equipment are exempt from RoHS compliance.
Certification EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, VDE
Management features
Monitoring Current,Power,Voltage
Outlet control Lock-out,Recycle,Turn off,Turn on
Power
Nominal input voltage The voltage which the manufacturer recommends that the device needs to operate normally. 230 V
AC input frequency 50 - 60 Hz
Maximum current The greatest possible amount of current, which is a quantity representing the rate of flow of electric charge. 32 A
Nominal output voltage The voltage which the manufacturer states that the device can produce. 230 V
Load capacity 7680 VA
Maximum input current per phase 32 A
Maximum total current draw per phase 32 A
Power protection features Features that protect the device against power problems e.g. overload. Overload
Maximum power The maximum power that can be put into or produced by the device. 7680 W
Weight & dimensions
Dimensions (WxDxH) Dimensions of the product (Width x Depth x Height). 56.00 x 51.00 x 1829.00 mm
Weight Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies. 8.23 kg
Packaging data
Package dimensions (WxDxH) Dimensions of the packaged product (Width x Depth x Height). 162.00 x 118.00 x 2038.00 mm
Package weight Weight of the packaged product. 10.5 kg
Operational conditions
Operating temperature (T-T) The minimum and maximum temperatures at which the product can be safely operated. -5 - 45 °C
Storage temperature (T-T) The minimum and maximum temperatures at which the product can be safely stored. -25 - 65 °C
Operating relative humidity (H-H) 5 - 95%
Storage relative humidity (H-H) 5 - 95%
Operating altitude 0 - 3000 m
Non-operating altitude 0 - 15000 m
More Information
SKU 458939
MPN AP8653
Brand APC
Product Condition Brand New/Unused
Stock Availability Available for Shipping
Product Use General
Warranty Period 1 Year Warranty