Skip to content

APC Switched 1U Rackmount PDU 12A/208V 10A/230V

Item No:
413931
MPN:
AP7920B
$1,760.87

APC Switched 1U Rackmount PDU 12A/208V 10A/230V

$1,760.87
Payment options
Shipping Information
  • Available for shipping
  • Usually leaves our partner warehouse in 2-4 business days
Store Availability
  • 3-5 business days at Bankstown Store
  • 3-5 business days at Castle Hill Store
  • 2-4 business days at Northmead Store
Shipping Estimate
APC AP7920B; PDU types: Metered,Switched, Rack capacity: 0U/1U, Mounting: Horizontal/Vertical; AC outlets quantity: 8 AC outlet(s), AC outlet types: C13 coupler, Power plug: C14 coupler; Cable length: 1.98 m, Certification: cUL Listed, CE, CSA, EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, GOST, IRAM, MIC, UL...; Monitoring: Current,Power,Voltage, Outlet control: Lock-out,Recycle,Turn off,Turn on; Nominal input voltage: 200-230 V, Maximum current: 10 A, AC input frequency: 50 - 60 Hz
Availability

Integrates with StruxureWare Data Center Expert
An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network.

Flash Upgradeable
Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released.

Local Current Monitoring Display
The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.

Alarm Thresholds
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.

Load indicator LED
Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.

Power Delays
Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.

Remote Individual Outlet Control
Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).

Network Management Capabilities
Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.

Marketing Features

Power Delays
Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.

Remote Individual Outlet Control
Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).

Local Current Monitoring Display
The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.

Remote Management Capabilities
Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.

Alarm Thresholds
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.

Agility

Wide range of input and output connections
Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.

Single input power source
Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.

Rack-Mountable
Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.
Design
PDU types A power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing, and remote monitoring and control by LAN or SNMP. Metered,Switched
Rack capacity The spase that device fill in rack. 0U/1U
Mounting What size the mounting head of the product is, to couple it with a camera. Horizontal/Vertical
Product colour The colour e.g. red, blue, green, black, white. Black
Ports & interfaces
AC outlets quantity The number of sockets in the device where AC electrical power can be connected. 8 AC outlet(s)
Power plug A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection. C14 coupler
AC outlet types The type of outlet for AC electricity. C13 coupler
Input connection type The type of connection /port for the input(s) into this device e.g. USB. IEC-320 C14
Features
Cable length How long the cable is. 1.98 m
RoHS compliance The Restriction of Hazardous Substances (RoHS) Directive aims to restrict certain dangerous substances commonly used in electrical and electronic equipment. Any RoHS compliant product is tested for the presence of Lead (Pb), Cadmium (Cd), Mercury (Hg), Hexavalent chromium (Hex-Cr), Polybrominated biphenyls (PBB), and Polybrominated diphenyl ethers (PBDE). PBB and PBDE are flame retardants used in several plastics. For Cadmium and Hexavalent chromium, there must be less than 0.01% of the substance by weight at raw homogeneous materials level. For Lead, PBB, and PBDE, there must be no more than 0.1% of the material, when calculated by weight at raw homogeneous materials. Any RoHS compliant component must have 100 ppm or less of mercury and the mercury must not have been intentionally added to the component. In the EU, some military and medical equipment are exempt from RoHS compliance.
Certification cUL Listed, CE, CSA, EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, GOST, IRAM, MIC, UL 60950, UL Listed, VDE, VCCI, REACH
Management features
Monitoring Current,Power,Voltage
Outlet control Lock-out,Recycle,Turn off,Turn on
Power
Nominal input voltage The voltage which the manufacturer recommends that the device needs to operate normally. 200-230 V
AC input frequency 50 - 60 Hz
Maximum current The greatest possible amount of current, which is a quantity representing the rate of flow of electric charge. 10 A
Nominal output voltage The voltage which the manufacturer states that the device can produce. 208-230 V
Load capacity 2300 VA
Maximum input current per phase 10 A
Maximum total current draw per phase 10 A
Maximum power The maximum power that can be put into or produced by the device. 2300 W
Weight & dimensions
Dimensions (WxDxH) Dimensions of the product (Width x Depth x Height). 445 x 108 x 44 mm
Weight Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies. 2.27 kg
Packaging data
Package dimensions (WxDxH) Dimensions of the packaged product (Width x Depth x Height). 470 x 343 x 70 mm
Package weight Weight of the packaged product. 3.45 kg
Packaging content
Packaging content Installation Guide, Rack Mounting Brackets, User Manual
Operational conditions
Operating temperature (T-T) The minimum and maximum temperatures at which the product can be safely operated. 0 - 45 °C
Storage temperature (T-T) The minimum and maximum temperatures at which the product can be safely stored. -25 - 65 °C
Operating relative humidity (H-H) 0 - 95%
Storage relative humidity (H-H) 0 - 95%
Operating altitude 0 - 3000 m
Non-operating altitude 1 - 15000 m
More Information
SKU 413931
MPN AP7920B
Brand APC
Product Condition Brand New/Unused
Stock Availability Available for Shipping
Product Use General
Warranty Period 2 Years Warranty
Warranty Contact https://www.apc.com/