Skip to content

APC Smart-UPS SRT 1500VA 230V 1500W

Item No:
414876
MPN:
SRT1500XLI
$2,989.87

APC Smart-UPS SRT 1500VA 230V 1500W

$2,989.87
Payment options
Shipping Information
  • ETA 17/12/2024 for shipping
  • Pre-order available, shipping ETA 17/12/2024
Store Availability
  • ETA 17/12/2024 at Bankstown Store
  • ETA 17/12/2024 at Castle Hill Store
Shipping Estimate
APC SRT1500XLI; UPS topology: Double-conversion (Online), Output power capacity: 1500 VA, Output power: 1500 W; Serial interface type: RJ-45; Battery technology: Sealed Lead Acid (VRLA), Battery life (max): 5 year(s), Battery recharge time: 3 h; Form factor: Rackmount/Tower, Product colour: Black, Cable length: 1.83 m; Width: 85 mm, Depth: 505 mm, Height: 432 mm
High density, double-conversion on-line power protection with scalable runtime
Includes: CD with software, Comms cable, Documentation CD, Installation guide, Removable support feet, USB cable, Warranty card

Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance

ECO Mode
Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection

LCD graphics display
Text and mimic diagrams that display modes of operation, system parameters and alarms.

Rack/Tower convertible
Protects the initial investment in the UPS when migrating from tower to rack-mount environment.

Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.

Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS power overload or fault.

Scalable runtime
Allows additional run time to be quickly added as needed.

Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced

Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.

Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.

LED status indicators
Quickly understand unit and power status with visual indicators.

Serial connectivity
Provides management of the UPS via a serial port.

InfraStruXure Manager Compatible
Enables centralized management via the APC InfraStruXure Manager.

SmartSlot
Customize UPS capabilities with management cards.

Network manageable
Provides remote power management of the UPS over the network.

Flash upgradeable firmware
Install maintenance releases of firmware remotely using FTP.

Plug-and-Play external batteries
Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.

Rack/Tower convertible
Protects the initial investment in the UPS when migrating from tower to rack-mount environment.

User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.

Predictive failure notification.
Provides early-warning fault analysis ensuring proactive component replacement.

Disconnected battery notification
Warns when a battery is not available to provide backup power.

Audible alarms
Provides notification of changing utility power and UPS power conditions

Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.

Cold-start capable
Provides temporary battery power when the utility power is out.

Frequency and voltage regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.

Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.

Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.

Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs)
Features
UPS topology The two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances. Double-conversion (Online)
Output power capacity The maximum power that the device can produce. 1500 VA
Output power The power that the device can produce. 1500 W
Waveform Sine
Input operation voltage (min) The minumum voltage needed by the device during operation. 100 V
Input operation voltage (max) The maximum input voltage supported by the device. 275 V
Input frequency The frequency (Hz) which is required to power the product. 40/70 Hz
Output operation voltage (min) The minumum voltage produced by the device during operation. 220 V
Output operation voltage (max) The maximum output voltage produced by the device. 240 V
Output frequency 50/60 Hz
Surge energy rating A surge protector is an appliance designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. The surge energy rating is a measure of how much energy a surge protector can theoretically absorb in a single event, without failure. 432 J
Crest factor 3:1
Emergency Power Off (EPO)
Noise level The amplitude level of the undesired background noise, usually measured in decibels (db). 50 dB
Audible alarm(s) Alarms that make a sound when they are activated (set off).
Ports & interfaces
USB port The device features a socket into which a USB cable can be plugged.
Serial interface
Serial interface type RJ-45
SmartSlot
Battery
Battery technology The type of battery in the device, e.g. nickel–cadmium (NiCd). Sealed Lead Acid (VRLA)
Battery life (max) 5 year(s)
Battery recharge time Approximate time required to recharge the battery from completely empty to completely full 3 h
Hot-swap battery
Design
Form factor The shape or design of the product. Rackmount/Tower
Cable length How long the cable is. 1.83 m
Product colour The colour e.g. red, blue, green, black, white. Black
LED indicators
Display The description of display that can includes display type, resolution, size etc. LCD
International Protection (IP) code The IP code classifies and rates the degree of protection provided against the intrusion (including body parts such as hands and fingers), dust, accidental contact, and water by mechanical casings and electrical enclosures. It is published by the International Electrotechnical Commission (IEC). The digits (characteristic numerals) indicate conformity with the conditions summarized in the tables below. Where there is no protection rating with regard to one of the criteria, the digit is replaced with the letter X. an electrical socket rated IP22 is protected against insertion of fingers and will not be damaged or become unsafe during a specified test in which it is exposed to vertically or nearly vertically dripping water. Another example is the Sony Xperia Z Ultra, one of the first cellular phones to be IP-rated; it is rated at IP58 and marketed as "dust resistant" and can be "immersed in 1.5 meter of freshwater for up to 30 minutes". IP20
RoHS compliance The Restriction of Hazardous Substances (RoHS) Directive aims to restrict certain dangerous substances commonly used in electrical and electronic equipment. Any RoHS compliant product is tested for the presence of Lead (Pb), Cadmium (Cd), Mercury (Hg), Hexavalent chromium (Hex-Cr), Polybrominated biphenyls (PBB), and Polybrominated diphenyl ethers (PBDE). PBB and PBDE are flame retardants used in several plastics. For Cadmium and Hexavalent chromium, there must be less than 0.01% of the substance by weight at raw homogeneous materials level. For Lead, PBB, and PBDE, there must be no more than 0.1% of the material, when calculated by weight at raw homogeneous materials. Any RoHS compliant component must have 100 ppm or less of mercury and the mercury must not have been intentionally added to the component. In the EU, some military and medical equipment are exempt from RoHS compliance.
Certification CE, EAC
Operational conditions
Operating temperature (T-T) The minimum and maximum temperatures at which the product can be safely operated. 0 - 40 °C
Storage temperature (T-T) The minimum and maximum temperatures at which the product can be safely stored. -20 - 50 °C
Operating relative humidity (H-H) 0 - 95%
Storage relative humidity (H-H) 0 - 95%
Weight & dimensions
Width The measurement or extent of something from side to side. 85 mm
Depth The distance from the front to the back of something. 505 mm
Height The measurement of the product from head to foot or from base to top. 432 mm
Weight Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies. 20.5 kg
Packaging data
Manual
Package width The distance from one side of the packaging to the other. 594 mm
Package depth The distance from the front to the back of the packaging. 749 mm
Package height The distance from the top to the bottom of the packaging. 246 mm
Package weight Weight of the packaged product. 29.6 kg
Logistics data
Quantity per pallet Quantity of a single product per pallet. If more than one product is packed per carton; this is the number of products (not number of cartons) per shipping pallet. 12 pc(s)
More Information
SKU 414876
MPN SRT1500XLI
Brand APC
Product Condition Brand New/Unused
Stock Availability Available for Shipping
Product Use General
Warranty Period 3 Years Warranty
Warranty Contact https://www.apc.com/