APC Smart-UPS On-Line; UPS topology: Double-conversion (Online), Output power capacity: 10000 VA, Output power: 10000 W; AC outlet types: C13 coupler,C19 coupler, Power plug: Terminal, AC outlets quantity: 10 AC outlet(s); Battery technology: Sealed Lead Acid (VRLA), Battery capacity: 1805 VAh, Typical backup time at full load: 3.8 min; Form factor: Rackmount/Tower, Product colour: Black, International Protection (IP) code: IP20; Width: 263 mm, Depth: 715 mm, Height: 432 mm
APC Smart-UPS On-Line,10 kW /10 kVA,Input 230V /Output 230V, Interface Port Contact Closure, RJ-45 10/100 Base-T, RJ-45 Serial, Smart-Slot, USB, Extended runtime model
Includes: CD with software, Documentation CD, Installation guide, Temperature Probe, USB cable, Warranty card
Includes: CD with software, Documentation CD, Installation guide, Temperature Probe, USB cable, Warranty card
| Features | |
| UPS topology The two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances. | Double-conversion (Online) |
| Output power capacity The maximum power that the device can produce. | 10000 VA |
| Output power The power that the device can produce. | 10000 W |
| Waveform | Sine |
| Input operation voltage (min) The minumum voltage needed by the device during operation. | 100 V |
| Input operation voltage (max) The maximum input voltage supported by the device. | 476 V |
| Input frequency The frequency (Hz) which is required to power the product. | 40/70 Hz |
| Output operation voltage (min) The minumum voltage produced by the device during operation. | 220 V |
| Output operation voltage (max) The maximum output voltage produced by the device. | 240 V |
| Output frequency regulation | 50/60 Hz |
| Surge energy rating A surge protector is an appliance designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. The surge energy rating is a measure of how much energy a surge protector can theoretically absorb in a single event, without failure. | 480 J |
| Number of output phases | 1 |
| Efficiency | 94.6% |
| Crest factor | 3:1 |
| Emergency Power Off (EPO) |
|
| Noise level The amplitude level of the undesired background noise, usually measured in decibels (db). | 55 dB |
| Audible alarm(s) Alarms that make a sound when they are activated (set off). |
|
| Auto-restart |
|
| Ports & interfaces | |
| AC outlet types The type of outlet for AC electricity. | C13 coupler,C19 coupler |
| Power plug A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection. | Terminal |
| AC outlets quantity The number of sockets in the device where AC electrical power can be connected. | 10 AC outlet(s) |
| Number of output IEC jumpers | 3 |
| USB port The device features a socket into which a USB cable can be plugged. |
|
| Serial interface |
|
| Serial interface type | RJ-45 |
| SmartSlot |
|
| Battery | |
| Battery technology The type of battery in the device, e.g. nickel–cadmium (NiCd). | Sealed Lead Acid (VRLA) |
| Battery capacity | 1805 VAh |
| Typical backup time at full load The amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is fully loaded (100% of capacity). | 3.8 min |
| Typical backup time at half load The amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity). | 11.5 min |
| Battery life (max) | 5 year(s) |
| Battery recharge time Approximate time required to recharge the battery from completely empty to completely full | 1.5 h |
| Hot-swap battery |
|
| Automatic battery test |
|
| Cold start |
|
| Design | |
| Form factor The shape or design of the product. | Rackmount/Tower |
| Product colour The colour e.g. red, blue, green, black, white. | Black |
| LED indicators |
|
| International Protection (IP) code The IP code classifies and rates the degree of protection provided against the intrusion (including body parts such as hands and fingers), dust, accidental contact, and water by mechanical casings and electrical enclosures. It is published by the International Electrotechnical Commission (IEC). The digits (characteristic numerals) indicate conformity with the conditions summarized in the tables below. Where there is no protection rating with regard to one of the criteria, the digit is replaced with the letter X. an electrical socket rated IP22 is protected against insertion of fingers and will not be damaged or become unsafe during a specified test in which it is exposed to vertically or nearly vertically dripping water. Another example is the Sony Xperia Z Ultra, one of the first cellular phones to be IP-rated; it is rated at IP58 and marketed as "dust resistant" and can be "immersed in 1.5 meter of freshwater for up to 30 minutes". | IP20 |
| Energy Star certified This indicates that the product is compliant with Energy Star, which is an international standard for energy-efficient consumer products. |
|
| RoHS compliance The Restriction of Hazardous Substances (RoHS) Directive aims to restrict certain dangerous substances commonly used in electrical and electronic equipment. Any RoHS compliant product is tested for the presence of Lead (Pb), Cadmium (Cd), Mercury (Hg), Hexavalent chromium (Hex-Cr), Polybrominated biphenyls (PBB), and Polybrominated diphenyl ethers (PBDE). PBB and PBDE are flame retardants used in several plastics. For Cadmium and Hexavalent chromium, there must be less than 0.01% of the substance by weight at raw homogeneous materials level. For Lead, PBB, and PBDE, there must be no more than 0.1% of the material, when calculated by weight at raw homogeneous materials. Any RoHS compliant component must have 100 ppm or less of mercury and the mercury must not have been intentionally added to the component. In the EU, some military and medical equipment are exempt from RoHS compliance. |
|
| Certification | CE, CE Mark, EAC, EN/IEC 62040-1, EN/IEC 62040-2, IRAM, RCM, VDE, REACH |
| Operational conditions | |
| Operating temperature (T-T) The minimum and maximum temperatures at which the product can be safely operated. | 0 - 40 °C |
| Storage temperature (T-T) The minimum and maximum temperatures at which the product can be safely stored. | -15 - 45 °C |
| Operating relative humidity (H-H) | 0 - 95% |
| Storage relative humidity (H-H) | 0 - 95% |
| Operating altitude | 0 - 3000 m |
| Non-operating altitude | 0 - 15000 m |
| Weight & dimensions | |
| Width The measurement or extent of something from side to side. | 263 mm |
| Depth The distance from the front to the back of something. | 715 mm |
| Height The measurement of the product from head to foot or from base to top. | 432 mm |
| Weight Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies. | 111.8 kg |
| Packaging data | |
| Cables included | USB cable |
| Temperature sensor |
|
| Quick installation guide |
|
| Warranty card |
|
| Software CD |
|
| Package width The distance from one side of the packaging to the other. | 600 mm |
| Package depth The distance from the front to the back of the packaging. | 1000 mm |
| Package height The distance from the top to the bottom of the packaging. | 461 mm |
| Package weight Weight of the packaged product. | 126.8 kg |
| Other features | |
| Interface Interface ports to connect pieces of equipment. USB (Universal Serial Bus) has become the most popular wired interface to connect peripherals. USB 2.0 supports speeds up to 480 Mbit/s (USB 1: 12 Mbit/s). The interface FireWire is also known as the IEEE 1394 standard. Enhanced IDE (EIDE)is sometimes referred to as Fast ATA, Fast IDE or ATA-2. | RJ-45 10/100 Base-T |
| Nominal output voltage The voltage which the manufacturer states that the device can produce. | 230 V |
| Nominal input voltage The voltage which the manufacturer recommends that the device needs to operate normally. | 230 V |
| Packaging content | Web/SNMP Management Card |
| SKU | 414855 |
| MPN | SRT10KXLI |
| Brand | APC |
| Product Condition | Brand New/Unused |
| Stock Availability | Available for Shipping |
| Product Use | General |
| Warranty Period | 2 Years Warranty |
| Warranty Contact | https://www.apc.com/ |