APC Smart-UPS; UPS topology: Line-Interactive, Output power capacity: 620 VA, Output power: 390 W; AC outlet types: C13 coupler, Power plug: C14 coupler, AC outlets quantity: 4 AC outlet(s); Battery technology: Sealed Lead Acid (VRLA), Battery capacity: 132 VAh, Typical backup time at full load: 5.5 min; Form factor: Tower, Product colour: Gray, LED indicators: Battery replacement; Width: 119 mm, Depth: 375 mm, Height: 168 mm
Features
UPS topology The two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances. Line-Interactive
Output power capacity The maximum power that the device can produce. 620 VA
Output power The power that the device can produce. 390 W
Waveform Sine
Input frequency The frequency (Hz) which is required to power the product. 50/60 Hz
Automatic Voltage Regulation (AVR)
Surge energy rating A surge protector is an appliance designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. The surge energy rating is a measure of how much energy a surge protector can theoretically absorb in a single event, without failure. 320 J
Hold time (max) 2 ms
Efficiency 97.4%
Emergency Power Off (EPO)
Noise level The amplitude level of the undesired background noise, usually measured in decibels (db). 45 dB
Surge protection
Surge protection features Digital Subscriber Line (DSL),Fax,Modem,Network
Audible alarm(s) Alarms that make a sound when they are activated (set off).
Audible alarm modes Low battery alarm,Overload alarm
Auto-restart
Ports & interfaces
AC outlet types The type of outlet for AC electricity. C13 coupler
Power plug A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection. C14 coupler
AC outlets quantity The number of sockets in the device where AC electrical power can be connected. 4 AC outlet(s)
Number of output IEC jumpers 2
Serial interface
Serial interface type RS-232
Serial ports quantity The number of serial ports in a computer or peripheral. A serial port is a serial communication physical interface through which information transfers in or out one bit at a time. The term "serial port" usually identifies hardware more or less compliant to the RS-232 standard, intended to interface with a modem or with a similar communication device. In modern computers and peripherals, serial ports have largely been replaced by USBs and other interfaces. 1
Battery
Battery technology The type of battery in the device, e.g. nickel–cadmium (NiCd). Sealed Lead Acid (VRLA)
Battery capacity 132 VAh
Typical backup time at full load The amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is fully loaded (100% of capacity). 5.5 min
Typical backup time at half load The amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity). 15.8 min
Battery life (max) 5 year(s)
Battery recharge time Approximate time required to recharge the battery from completely empty to completely full 5.5 h
Automatic battery test
Design
Form factor The shape or design of the product. Tower
Product colour The colour e.g. red, blue, green, black, white. Gray
LED indicators Battery replacement
RoHS compliance The Restriction of Hazardous Substances (RoHS) Directive aims to restrict certain dangerous substances commonly used in electrical and electronic equipment. Any RoHS compliant product is tested for the presence of Lead (Pb), Cadmium (Cd), Mercury (Hg), Hexavalent chromium (Hex-Cr), Polybrominated biphenyls (PBB), and Polybrominated diphenyl ethers (PBDE). PBB and PBDE are flame retardants used in several plastics. For Cadmium and Hexavalent chromium, there must be less than 0.01% of the substance by weight at raw homogeneous materials level. For Lead, PBB, and PBDE, there must be no more than 0.1% of the material, when calculated by weight at raw homogeneous materials. Any RoHS compliant component must have 100 ppm or less of mercury and the mercury must not have been intentionally added to the component. In the EU, some military and medical equipment are exempt from RoHS compliance.
Certification REACH, PEP, EOLI
Operational conditions
Operating temperature (T-T) The minimum and maximum temperatures at which the product can be safely operated. 0 - 40 °C
Storage temperature (T-T) The minimum and maximum temperatures at which the product can be safely stored. -15 - 45 °C
Operating relative humidity (H-H) 0 - 95%
Storage relative humidity (H-H) 0 - 95%
Operating altitude 0 - 3000 m
Non-operating altitude 0 - 15000 m
Weight & dimensions
Width The measurement or extent of something from side to side. 119 mm
Depth The distance from the front to the back of something. 375 mm
Height The measurement of the product from head to foot or from base to top. 168 mm
Weight Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies. 12.3 kg
Packaging data
Cables included RS-232
Manual
Software CD
Package width The distance from one side of the packaging to the other. 262 mm
Package depth The distance from the front to the back of the packaging. 508 mm
Package height The distance from the top to the bottom of the packaging. 318 mm
Package weight Weight of the packaged product. 13.2 kg
Logistics data
Quantity per pallet Quantity of a single product per pallet. If more than one product is packed per carton; this is the number of products (not number of cartons) per shipping pallet. 12 pc(s)
Other features
Nominal output voltage The voltage which the manufacturer states that the device can produce. 230 V
Nominal input voltage The voltage which the manufacturer recommends that the device needs to operate normally. 230 V
More Information
SKU 414526
MPN SC620I
Brand APC
Product Condition Brand New/Unused
Stock Availability Available for Shipping
Product Use General
Warranty Period 2 Years Warranty
Warranty Contact https://www.apc.com/