Shipping Information
- Available for shipping
- Usually leaves our partner warehouse in 2-4 business days
Store Availability
- 3-5 business days at Bankstown Store
- 3-5 business days at Castle Hill Store
- 2-4 business days at Northmead Store
Shipping Estimate
APC SMT750RMI2UC; UPS topology: Line-Interactive, Output power capacity: 750 VA, Output power: 500 W; AC outlet types: C13 coupler, Power plug: C14 coupler, AC outlets quantity: 4 AC outlet(s); Battery technology: Sealed Lead Acid (VRLA), Battery capacity: 168 VAh, Typical backup time at full load: 5.5 min; Form factor: Rackmount, Product colour: Black, LED indicators: Battery replacement; Width: 432 mm, Depth: 406 mm, Height: 89 mm
Intelligent and efficient network power protection from entry level to scaleable runtime. Ideal UPS for servers, point-of-sale, routers, switches, hubs and other network devices.
Includes: CD with software, Documentation CD, Installation guide, Rack Mounting support rails, USB cable
Cold-start capable
Provides temporary battery power when the utility power is out.
Energy meter
Provides actual kilowatt hours of usage for energy conscious users.
Green mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
High online efficiency
Reduces utility costs, generates less heat.
Intuitive LCD interface
Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.
Predictive replace battery date
Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.
Pure sine wave output on battery
Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.
Single switched outlet group
Single outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.
SmartConnect
Innovative, easy to use remote monitoring feature that provides automatic notifications, firmware updates, and advanced support services.
SmartSlot
Customize UPS capabilities with management cards.
Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Adjustable voltage-transfer points
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
Adjustable voltage sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or generat
Resettable circuit breakers
Enables a quick recovery from overload events.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Predictive failure notification.
Provides early-warning fault analysis ensuring proactive component replacement.
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Includes: CD with software, Documentation CD, Installation guide, Rack Mounting support rails, USB cable
Cold-start capable
Provides temporary battery power when the utility power is out.
Energy meter
Provides actual kilowatt hours of usage for energy conscious users.
Green mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
High online efficiency
Reduces utility costs, generates less heat.
Intuitive LCD interface
Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.
Predictive replace battery date
Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.
Pure sine wave output on battery
Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.
Single switched outlet group
Single outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.
SmartConnect
Innovative, easy to use remote monitoring feature that provides automatic notifications, firmware updates, and advanced support services.
SmartSlot
Customize UPS capabilities with management cards.
Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Adjustable voltage-transfer points
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
Adjustable voltage sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or generat
Resettable circuit breakers
Enables a quick recovery from overload events.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Predictive failure notification.
Provides early-warning fault analysis ensuring proactive component replacement.
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
| Features | |
| UPS topology The two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances. | Line-Interactive |
| Output power capacity The maximum power that the device can produce. | 750 VA |
| Output power The power that the device can produce. | 500 W |
| Waveform | Sine |
| Input operation voltage (min) The minumum voltage needed by the device during operation. | 151 V |
| Input operation voltage (max) The maximum input voltage supported by the device. | 302 V |
| Input frequency The frequency (Hz) which is required to power the product. | 50/60 Hz |
| Output operation voltage (min) The minumum voltage produced by the device during operation. | 220 V |
| Output operation voltage (max) The maximum output voltage produced by the device. | 240 V |
| Automatic Voltage Regulation (AVR) |
|
| Surge energy rating A surge protector is an appliance designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. The surge energy rating is a measure of how much energy a surge protector can theoretically absorb in a single event, without failure. | 459 J |
| Hold time (max) | 2 ms |
| Efficiency | 97.7% |
| Noise level The amplitude level of the undesired background noise, usually measured in decibels (db). | 42 dB |
| Surge protection |
|
| Audible alarm(s) Alarms that make a sound when they are activated (set off). |
|
| Auto-restart |
|
| Ports & interfaces | |
| AC outlet types The type of outlet for AC electricity. | C13 coupler |
| Power plug A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection. | C14 coupler |
| AC outlets quantity The number of sockets in the device where AC electrical power can be connected. | 4 AC outlet(s) |
| Number of output IEC jumpers | 2 |
| USB port The device features a socket into which a USB cable can be plugged. |
|
| Serial interface |
|
| Serial interface type | RJ-45 |
| SmartSlot |
|
| Battery | |
| Battery technology The type of battery in the device, e.g. nickel–cadmium (NiCd). | Sealed Lead Acid (VRLA) |
| Battery capacity | 168 VAh |
| Typical backup time at full load The amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is fully loaded (100% of capacity). | 5.5 min |
| Typical backup time at half load The amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity). | 16 min |
| Battery life (max) | 5 year(s) |
| Battery recharge time Approximate time required to recharge the battery from completely empty to completely full | 3 h |
| Hot-swap battery |
|
| Automatic battery test |
|
| Cold start |
|
| Design | |
| Form factor The shape or design of the product. | Rackmount |
| Product colour The colour e.g. red, blue, green, black, white. | Black |
| LED indicators | Battery replacement |
| RoHS compliance The Restriction of Hazardous Substances (RoHS) Directive aims to restrict certain dangerous substances commonly used in electrical and electronic equipment. Any RoHS compliant product is tested for the presence of Lead (Pb), Cadmium (Cd), Mercury (Hg), Hexavalent chromium (Hex-Cr), Polybrominated biphenyls (PBB), and Polybrominated diphenyl ethers (PBDE). PBB and PBDE are flame retardants used in several plastics. For Cadmium and Hexavalent chromium, there must be less than 0.01% of the substance by weight at raw homogeneous materials level. For Lead, PBB, and PBDE, there must be no more than 0.1% of the material, when calculated by weight at raw homogeneous materials. Any RoHS compliant component must have 100 ppm or less of mercury and the mercury must not have been intentionally added to the component. In the EU, some military and medical equipment are exempt from RoHS compliance. |
|
| Certification | CE, CSA, EAC, EN/IEC 62040-1, EN/IEC 62040-2, RCM, TUV, UL 1778, VDE, REACH, PEP, EOLI |
| Operational conditions | |
| Operating temperature (T-T) The minimum and maximum temperatures at which the product can be safely operated. | 0 - 40 °C |
| Storage temperature (T-T) The minimum and maximum temperatures at which the product can be safely stored. | -15 - 45 °C |
| Operating relative humidity (H-H) | 0 - 95% |
| Storage relative humidity (H-H) | 0 - 95% |
| Operating altitude | 0 - 3000 m |
| Non-operating altitude | 0 - 15000 m |
| Weight & dimensions | |
| Width The measurement or extent of something from side to side. | 432 mm |
| Depth The distance from the front to the back of something. | 406 mm |
| Height The measurement of the product from head to foot or from base to top. | 89 mm |
| Weight Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies. | 17.3 kg |
| Packaging data | |
| Rack mount kit |
|
| Cables included | RS-232,USB cable |
| Quick installation guide |
|
| Software CD |
|
| Package width The distance from one side of the packaging to the other. | 546 mm |
| Package depth The distance from the front to the back of the packaging. | 584 mm |
| Package height The distance from the top to the bottom of the packaging. | 241 mm |
| Package weight Weight of the packaged product. | 21.2 kg |
| Logistics data | |
| Quantity per pallet Quantity of a single product per pallet. If more than one product is packed per carton; this is the number of products (not number of cartons) per shipping pallet. | 16 pc(s) |
| SKU | 414666 |
| MPN | SMT750RMI2UC |
| Brand | APC |
| Product Condition | Brand New/Unused |
| Stock Availability | Available for Shipping |
| Product Use | General |
| Warranty Period | 3 Years Warranty |
| Warranty Contact | https://www.apc.com/ |