New
APC Rack PDU Adv Metered 2U 3 Phase 415V
Item No:
846235
MPN:
APDU11454ME
$6,435.00
Payment options
Shipping Information
- Unavailable for shipping
- This product is not currently available for purchase
Store Availability
- Unavailable at Bankstown Store
- Unavailable at Castle Hill Store
- Unavailable at Northmead Store
APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets, Metered, 2U, Three-phase, Horizontal, Black, 18 AC outlet(s)
APC NetShelter Rack PDU Advanced (11K Series) provides reliable power distribution to IT equipment within server and/or networking racks. PDU level power metering provides power visibility and notification of potential overload. 50 percent of outlets on model are designed as 4 in 1 combination outlets which can be used as either C13, C19, C15, or C21 to provide unparalleled deployment flexibility. Outlets on the PDUs are color coded and labeled by breaker. Live Swap the NMC3 to minimize downtime in the unlikely event of an NMC power event. The rack PDU integrates with EcoStruxure IT through an NMC3 and can be accessed and configured via web, SNMP, and command line interface (CLI). Rated to operate up to 60 C (140 F) at full load ensures reliability and availability even in today s high density deployments. One gigabit Ethernet/network port (10/100/1000) enhances and standardizes network connectivity. Two link ports are available to cascade to up to 32 PDUs, with a network port sharing (NPS) feature to enable power sharing between Rack PDUs in the cascading group. Track or bill power usage confidently with 1% metering accuracy. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs have the following certifications: UL, CE, CSA, UKCA, Nemiko, PSE, KC, China RoHS, RCM, and CMIM. This model's input power cord is 560P6 or 563P6 and features 9 count C13/C15 and 9 count C13/C15/C19/C21 outlets. A 9.8 foot (3 meter) input cord makes it easier for the PDU to reach the power supply.
| Design | |
| PDU types A power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing, and remote monitoring and control by LAN or SNMP. | Metered |
| Type Characteristics of the device. | Three-phase |
| Rack capacity The spase that device fill in rack. | 2U |
| Mounting What size the mounting head of the product is, to couple it with a camera. | Horizontal |
| Product colour The colour e.g. red, blue, green, black, white. | Black |
| Upgradeable Indicates whether the product can be expanded or improved through the addition of new components or software updates. |
|
| Ports & interfaces | |
| AC outlets quantity The number of sockets in the device where AC electrical power can be connected. | 18 AC outlet(s) |
| Power plug A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection. | IEC309 |
| AC outlet types The type of outlet for AC electricity. | C13 coupler, C15 coupler, C19 coupler, C21 coupler |
| Input connection type The type of connection /port for the input(s) into this device e.g. USB. | IEC 309 60 A |
| Features | |
| International Protection (IP) code The IP code classifies and rates the degree of protection provided against the intrusion (including body parts such as hands and fingers), dust, accidental contact, and water by mechanical casings and electrical enclosures. It is published by the International Electrotechnical Commission (IEC). The digits (characteristic numerals) indicate conformity with the conditions summarized in the tables below. Where there is no protection rating with regard to one of the criteria, the digit is replaced with the letter X. an electrical socket rated IP22 is protected against insertion of fingers and will not be damaged or become unsafe during a specified test in which it is exposed to vertically or nearly vertically dripping water. Another example is the Sony Xperia Z Ultra, one of the first cellular phones to be IP-rated; it is rated at IP58 and marketed as "dust resistant" and can be "immersed in 1.5 meter of freshwater for up to 30 minutes". | IP44 |
| Management features | |
| Management platform The software or cloud-based system used to configure, monitor, and control the device (e.g., Cloudpath or EPICenter Network Management Software). | NMC3 |
| Power | |
| Nominal input voltage The voltage which the manufacturer recommends that the device needs to operate normally. | 415 3 phases |
| AC input frequency The range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65). | 50/60 Hz |
| Maximum current The greatest possible amount of current, which is a quantity representing the rate of flow of electric charge. | 60 A |
| Output voltage The electrical potential difference delivered by the device, typically expressed in volts (e.g. 24-48). | 415 V AC 3 phases |
| Load capacity The maximum apparent power that the device can safely handle, measured in VA. | 41400 VA |
| Number of phases The total number of power stages or phases used to regulate and distribute electrical current to the components. | 3 |
| Certificates | |
| Waste Electrical and Electronic Equipment (WEEE) compliance Indicates whether the product complies with the Waste Electrical and Electronic Equipment (WEEE) directive regarding the disposal and recycling of electronic waste. |
|
| Compliance certificates Indicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies. | RoHS, REACH, WEEE |
| Sustainability | |
| Doesn't contain Specifies the harmful or restricted substances that are not present in the product (e.g. Acetone, Alcohol, or Aluminium). | Silicone |
| Operational conditions | |
| Operating temperature (T-T) The minimum and maximum temperatures at which the product can be safely operated. | -5 - 60 °C |
| Storage temperature (T-T) The minimum and maximum temperatures at which the product can be safely stored. | -20 - 60 °C |
| Operating relative humidity (H-H) The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss. | 5 - 90% |
| Storage relative humidity (H-H) The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage. | 5 - 95% |
| Non-operating altitude The maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres. | 0 - 15240 m |
| Weight & dimensions | |
| Width The measurement or extent of something from side to side. | 443 mm |
| Depth The distance from the front to the back of something. | 750 mm |
| Height The measurement of the product from head to foot or from base to top. | 85 mm |
| Weight Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies. | 15.7 kg |
| Packaging data | |
| Package weight Weight of the packaged product. | 22.2 kg |
| Package width The distance from one side of the packaging to the other. | 600 mm |
| Package depth The distance from the front to the back of the packaging. | 165 mm |
| Package height The distance from the top to the bottom of the packaging. | 940 mm |
| Technical details | |
| Sustainable packaging Indicates whether the product is delivered in packaging made from environmentally friendly or recycled materials. |
|
| Packaging recycled materials Identifies which specific recycled or secondary material types are present in the packaging. | Recycled cardboard |
| SCIP number The unique identification number assigned to a product containing substances of very high concern (SVHC) to comply with EU waste regulations. | 7547f066-9302-46d9-96e9-461928dd6901 |
| Preferred mounting position The recommended orientation or location for installing the unit to ensure optimal performance and stability (e.g. wall, ceiling, or desk). | no preference |
| Take-back system Take-back system allow consumers to return used products to manufacturers or retailers for reuse, recycling, or responsible disposal. |
|
| Packaging without single use plastic Indicates whether the product is delivered in packaging that does not contain any single-use plastics. |
|
| Logistics data | |
| Customs product code (TARIC) The integrated Tariff of the European Union code used to identify the product for customs and trade purposes. | 8537109899 |
| SKU | 846235 |
| MPN | APDU11454ME |
| Brand | APC |
| Product Condition | Brand New/Unused |
| Product Use | General |
| Warranty Period | 1 Year Warranty |
| Warranty Contact | https://www.apc.com/ |