APC AP7822B, Metered, 2U, Single-phase, Horizontal/Vertical, Black, 16 AC outlet(s)
Resettable circuit breakers
Enables a quick recovery from overload events.

Load indicator LED
Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.

Alarm Thresholds
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)

Flash Upgradeable
Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)

Integrates with StruxureWare Data Center Expert
An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network

Local Current Monitoring Display
The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)

Remote Management Capabilities
Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
Design
PDU types A power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing, and remote monitoring and control by LAN or SNMP. Metered
Type Characteristics of the device. Single-phase
Rack capacity The spase that device fill in rack. 2U
Mounting What size the mounting head of the product is, to couple it with a camera. Horizontal/Vertical
Product colour The colour e.g. red, blue, green, black, white. Black
On/off switch The button which is pressed to switch the device on or off.
Ports & interfaces
AC outlets quantity The number of sockets in the device where AC electrical power can be connected. 16 AC outlet(s)
Power plug A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection. IEC309
AC outlet types The type of outlet for AC electricity. C13 coupler,C19 coupler
Input connection type The type of connection /port for the input(s) into this device e.g. USB. IEC 309 32A 2P+E
Output connections 12 x C13 4 x C19
Features
LED indicators
Cable length How long the cable is. 3.66 m
RoHS compliance The Restriction of Hazardous Substances (RoHS) Directive aims to restrict certain dangerous substances commonly used in electrical and electronic equipment. Any RoHS compliant product is tested for the presence of Lead (Pb), Cadmium (Cd), Mercury (Hg), Hexavalent chromium (Hex-Cr), Polybrominated biphenyls (PBB), and Polybrominated diphenyl ethers (PBDE). PBB and PBDE are flame retardants used in several plastics. For Cadmium and Hexavalent chromium, there must be less than 0.01% of the substance by weight at raw homogeneous materials level. For Lead, PBB, and PBDE, there must be no more than 0.1% of the material, when calculated by weight at raw homogeneous materials. Any RoHS compliant component must have 100 ppm or less of mercury and the mercury must not have been intentionally added to the component. In the EU, some military and medical equipment are exempt from RoHS compliance.
Certification C-tick, CE, FCC 15 A, GOST, ICES-003, IRAM, MIC, VDE, VCCI
Management features
Monitoring Current,Power,Voltage
Power
Nominal input voltage The voltage which the manufacturer recommends that the device needs to operate normally. 208-230 V
AC input frequency 50 - 60 Hz
Maximum current The greatest possible amount of current, which is a quantity representing the rate of flow of electric charge. 32 A
Load capacity 7680 VA
Maximum input current per phase 32 A
Maximum total current draw per phase 32 A
Power protection features Features that protect the device against power problems e.g. overload. Overload
Maximum power The maximum power that can be put into or produced by the device. 7680 W
Weight & dimensions
Dimensions (WxDxH) Dimensions of the product (Width x Depth x Height). 444 x 112 x 88 mm
Weight Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies. 3.36 kg
Packaging data
Package dimensions (WxDxH) Dimensions of the packaged product (Width x Depth x Height). 508 x 368 x 140 mm
Package weight Weight of the packaged product. 5.41 kg
Operational conditions
Operating temperature (T-T) The minimum and maximum temperatures at which the product can be safely operated. -5 - 45 °C
Storage temperature (T-T) The minimum and maximum temperatures at which the product can be safely stored. -25 - 65 °C
Operating relative humidity (H-H) 5 - 95%
Storage relative humidity (H-H) 5 - 95%
More Information
SKU 455717
MPN AP7822B
Brand APC
Product Condition Brand New/Unused
Stock Availability Available for Shipping
Product Use General
Warranty Period 2 Years Warranty