APC NetShelter Rack PDU Advanced Metered 3PH

Item No:
792041
MPN:
APDU10450ME
$5,150.00
Payment options

This product is currently not available!

Shipping Information
  • Unavailable for shipping
  • This product is not currently available for purchase
Store Availability
  • Unavailable at Bankstown Store
  • Unavailable at Castle Hill Store
  • Unavailable at Northmead Store
APC APDU10450ME, Switched, 0U, Single-phase, Vertical, Black, LCD
APC NetShelter Rack PDU Advanced, Metered, 34.6kW, 3PH, 415V, 60A, 560P6, 42 Outlet
APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 42 outlets in a 2.2" wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today s high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.
Design
PDU types A power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing, and remote monitoring and control by LAN or SNMP. Switched
Type Characteristics of the device. Single-phase
Rack capacity The spase that device fill in rack. 0U
Mounting What size the mounting head of the product is, to couple it with a camera. Vertical
Product colour The colour e.g. red, blue, green, black, white. Black
Display The description of display that can includes display type, resolution, size etc. LCD
On/off switch The button which is pressed to switch the device on or off.
Ports & interfaces
AC outlets quantity The number of sockets in the device where AC electrical power can be connected. 48 AC outlet(s)
Power plug A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection. IEC 60309
AC outlet types The type of outlet for AC electricity. C13 coupler, C15 coupler, C19 coupler, C21 coupler
Features
Daisy chain
Certification CSA C22.2 No 62368-1, FCC part 15 subpart B, UL 62368-1
Power
Nominal input voltage The voltage which the manufacturer recommends that the device needs to operate normally. 415 V
AC input frequency 50 - 60 Hz
Maximum current The greatest possible amount of current, which is a quantity representing the rate of flow of electric charge. 60 A
Nominal output voltage The voltage which the manufacturer states that the device can produce. 240 V
Output voltage 240 V
Load capacity 34600 VA
Maximum input current per phase 60 A
Maximum total current draw per phase 48 A
Weight & dimensions
Width The measurement or extent of something from side to side. 56 mm
Depth The distance from the front to the back of something. 75 mm
Height The measurement of the product from head to foot or from base to top. 1826 mm
Weight Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies. 11.7 kg
Packaging data
Package weight Weight of the packaged product. 14.7 kg
Package width The distance from one side of the packaging to the other. 262 mm
Package depth The distance from the front to the back of the packaging. 132 mm
Package height The distance from the top to the bottom of the packaging. 1980 mm
Operational conditions
Operating temperature (T-T) The minimum and maximum temperatures at which the product can be safely operated. -5 - 60 °C
Storage temperature (T-T) The minimum and maximum temperatures at which the product can be safely stored. -25 - 65 °C
Operating relative humidity (H-H) 5 - 95%
Storage relative humidity (H-H) 5 - 95%
Operating altitude 0 - 3048 m
Non-operating altitude 0 - 15240 m
More Information
SKU 792041
MPN APDU10450ME
Brand APC
Product Condition Brand New/Unused
Stock Availability Available for Shipping
Product Use General
Warranty Period 1 Year Warranty
Warranty Contact https://www.apc.com/