APC GALAXY VS, Double-conversion (Online), 50 kVA, 50000 W, Sine, 340 V, 460 V
Galaxy VS UPS 50kW 400V with N+1 power module, for 5 smart modular 9Ah battery strings, Start-up 5x8
Highly efficient, easy-to-deploy 50kW, 400V 3-phase UPS that brings best-in-class power protection and low total cost of ownership to edge, small and medium data centers, as well as to critical infrastructure in commercial and industrial applications. This UPS is for up to 5 smart modular high capacity battery strings, but is supplied without batteries, so you can easily customize the battery runtime. Includes 5x8 start-up service and one additional power module for N+1 redundancy.
Includes: Dust filter, EcoStruxure Ready, Installation Manual, Integrated network management, Start-up service.

Compatible with Schneider Electric's lithium ion battery solution
Reduces system footprint and weight, cooling and maintenance requirements, and total cost of ownership; offers double the life of VRLA batteries; and improves backup storage predictability and manageability.

Embedded Network Management Card
Allows you to remotely manage alert thresholds and monitor your UPS over EcoStruxure IT, Web, SNMP, or Modbus TCP and Modbus RTU.

Built-in backfeed protection
Full built-in backfeed contactor ensures that no electricity is sent back to the grid.

Parallel-redundant capable
Power the connected equipment with multiple uninterruptible power supplies to increase system redundancy

Flexible DC bus
Optimizes battery sizing and supports a wide range of energy storage technologies, including VRLA, Li-ion, and NiCd batteries.

Parallel-capacity capable
Increases total power capacity by using multiple uninterruptible power supplies simultaneously.

EcoStruxure IT Expert
From your smartphone or computer, connect to our cloud-based, do-it-yourself monitoring system that collects, organizes, and distributes critical alerts and key information in real time, providing a unified view of even highly distributed physical infrastructure environments. Optimize your uptime and maintenance planning, and anticipate infrastructure issues before they occur with advanced analytics and performance benchmarking. Available in select countries.

Front-access servicing
Simplifies installation and UPS maintenance while minimizing space requirements.

Modular UPS design
Provides design redundancy and fast serviceability with improved mean time to repair, via self-diagnosing, field-replaceable modules.

Multiple levels of service offers
With the option of packages or individual service components, our services are structured to allow you to pick and choose what you would like Schneider Electric to do for you.

ECOnversion mode
Operating mode that ensures ultra high efficiency while charging the batteries, conditioning the load power factor and ensuring a Class 1 output voltage regulation.

High efficiency in double conversion mode
Consistently high power quality at high efficiency, even at low load levels. Any disturbances on the distribution waveform are regenerated via the zero transfer time AC to DC then DC to AC conversion process. The battery is only used as a back-up source.

Input Power Factor Correction
Minimizes installation costs by enabling the use of smaller generators and cabling.

Robust operation
No power derating in kW up to 40 degrees C or 104 degrees F.

Wide input voltage range
Designed for harsh electrical environments to save battery life.
Features
UPS topology The two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances. Double-conversion (Online)
Output power capacity The maximum power that the device can produce. 50 kVA
Output power The power that the device can produce. 50000 W
Waveform Sine
Input operation voltage (min) The minumum voltage needed by the device during operation. 340 V
Input operation voltage (max) The maximum input voltage supported by the device. 460 V
Input frequency The frequency (Hz) which is required to power the product. 40/70 Hz
Output operation voltage (min) The minumum voltage produced by the device during operation. 380 V
Output operation voltage (max) The maximum output voltage produced by the device. 415 V
Output frequency 50/60 Hz
Output voltage regulation -0.1%
Input power factor 0.99
Crest factor 2.5:1
ECO mode
Output voltage Total Harmonic Distortion (THD) 3%
Input current Total Harmonic Distortion (THD) 3%
Noise level The amplitude level of the undesired background noise, usually measured in decibels (db). 54 dB
Audible alarm(s) Alarms that make a sound when they are activated (set off).
Battery
Battery technology The type of battery in the device, e.g. nickel–cadmium (NiCd). Sealed Lead Acid (VRLA)
Battery voltage The voltage (V) of the battery. 480 V
Charging current 136 A
Design
Form factor The shape or design of the product. Mini Tower
Product colour The colour e.g. red, blue, green, black, white. White
Display type Type of display (screen) e.g. LCD. LCD
International Protection (IP) code The IP code classifies and rates the degree of protection provided against the intrusion (including body parts such as hands and fingers), dust, accidental contact, and water by mechanical casings and electrical enclosures. It is published by the International Electrotechnical Commission (IEC). The digits (characteristic numerals) indicate conformity with the conditions summarized in the tables below. Where there is no protection rating with regard to one of the criteria, the digit is replaced with the letter X. an electrical socket rated IP22 is protected against insertion of fingers and will not be damaged or become unsafe during a specified test in which it is exposed to vertically or nearly vertically dripping water. Another example is the Sony Xperia Z Ultra, one of the first cellular phones to be IP-rated; it is rated at IP58 and marketed as "dust resistant" and can be "immersed in 1.5 meter of freshwater for up to 30 minutes". IP20
Operational conditions
Operating temperature (T-T) The minimum and maximum temperatures at which the product can be safely operated. 0 - 40 °C
Storage temperature (T-T) The minimum and maximum temperatures at which the product can be safely stored. -15 - 40 °C
Operating relative humidity (H-H) 0 - 95%
Storage relative humidity (H-H) 10 - 80%
Operating altitude 0 - 990 m
Technical details
Compliance certificates RoHS
Weight & dimensions
Width The measurement or extent of something from side to side. 550 mm
Depth The distance from the front to the back of something. 847 mm
Height The measurement of the product from head to foot or from base to top. 1970 mm
Weight Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies. 250 kg
Package width The distance from one side of the packaging to the other. 755 mm
Package depth The distance from the front to the back of the packaging. 1010 mm
Package height The distance from the top to the bottom of the packaging. 2082 mm
Package weight Weight of the packaged product. 250 kg
Logistics data
Harmonized System (HS) code 85078000
More Information
SKU 809069
MPN GVSUPS50KR0B5HS
Brand APC
Product Condition Brand New/Unused
Product Use General
Warranty Period 1 Year Warranty
Warranty Contact https://www.apc.com/