This APC Single phase Easy UPS is designed for IT professionals or network administrators to maintain business uptime and continuity. This 6kVA double-conversion on-line 5U rackmount UPS provides pure sine wave power and extended runtime to support critical electronics during power disruptions.
| Features | |
| UPS topology The two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances. | Double-conversion (Online) |
| Output power capacity The maximum power that the device can produce. | 6 kVA |
| Output power The power that the device can produce. | 6000 W |
| Waveform | Pure sine |
| Input operation voltage (min) The minumum voltage needed by the device during operation. | 110 V |
| Input operation voltage (max) The maximum input voltage supported by the device. | 300 V |
| Input frequency The frequency (Hz) which is required to power the product. | 40/70 Hz |
| Output operation voltage (min) The minumum voltage produced by the device during operation. | 220 V |
| Output operation voltage (max) The maximum output voltage produced by the device. | 240 V |
| Output frequency | 50/60 Hz |
| Surge energy rating A surge protector is an appliance designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. The surge energy rating is a measure of how much energy a surge protector can theoretically absorb in a single event, without failure. | 600 J |
| Efficiency | 94% |
| Crest factor | 3:1 |
| Output voltage Total Harmonic Distortion (THD) | 1% |
| Noise level The amplitude level of the undesired background noise, usually measured in decibels (db). | 55 dB |
| Surge protection |
|
| Audible alarm(s) Alarms that make a sound when they are activated (set off). |
|
| Audible alarm modes | Alarm when on battery, Low battery alarm, Overload alarm |
| Auto shut-off |
|
| Power source type What the power source is. | AC |
| Detachable power cord |
|
| Ports & interfaces | |
| USB port The device features a socket into which a USB cable can be plugged. |
|
| Battery | |
| Battery technology The type of battery in the device, e.g. nickel–cadmium (NiCd). | Sealed Lead Acid (VRLA) |
| Battery voltage The voltage (V) of the battery. | 240 V |
| Battery life (max) | 5 year(s) |
| Battery recharge time Approximate time required to recharge the battery from completely empty to completely full | 9 h |
| Hot-swap battery |
|
| Design | |
| Form factor The shape or design of the product. | Rackmount |
| Rack capacity The spase that device fill in rack. | 5U |
| Product colour The colour e.g. red, blue, green, black, white. | Black |
| Display type Type of display (screen) e.g. LCD. | LCD |
| International Protection (IP) code The IP code classifies and rates the degree of protection provided against the intrusion (including body parts such as hands and fingers), dust, accidental contact, and water by mechanical casings and electrical enclosures. It is published by the International Electrotechnical Commission (IEC). The digits (characteristic numerals) indicate conformity with the conditions summarized in the tables below. Where there is no protection rating with regard to one of the criteria, the digit is replaced with the letter X. an electrical socket rated IP22 is protected against insertion of fingers and will not be damaged or become unsafe during a specified test in which it is exposed to vertically or nearly vertically dripping water. Another example is the Sony Xperia Z Ultra, one of the first cellular phones to be IP-rated; it is rated at IP58 and marketed as "dust resistant" and can be "immersed in 1.5 meter of freshwater for up to 30 minutes". | IP20 |
| Operational conditions | |
| Operating temperature (T-T) The minimum and maximum temperatures at which the product can be safely operated. | 0 - 40 °C |
| Storage temperature (T-T) The minimum and maximum temperatures at which the product can be safely stored. | -15 - 60 °C |
| Operating relative humidity (H-H) | 0 - 95% |
| Storage relative humidity (H-H) | 0 - 95% |
| Operating altitude | 0 - 3000 m |
| Non-operating altitude | 0 - 15000 m |
| Certificates | |
| Certification | CE, UKCA, EAC, TISI |
| Packaging content | |
| Rack mount kit |
|
| Cables included | RS-232, USB cable |
| Manual |
|
| Weight & dimensions | |
| Width The measurement or extent of something from side to side. | 438 mm |
| Depth The distance from the front to the back of something. | 615 mm |
| Height The measurement of the product from head to foot or from base to top. | 220 mm |
| Weight Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies. | 78 kg |
| Logistics data | |
| Harmonized System (HS) code | 85078000 |
| SKU | 814130 |
| MPN | SRV6KRILRK |
| Brand | APC |
| Product Condition | Brand New/Unused |
| Stock Availability | Available for Shipping |
| Product Use | General |
| Warranty Period | 1 Year Warranty |
| Warranty Contact | https://www.apc.com/ |