Skip to content

APC Automatic Voltage Regulator 600VA - Beige

Item No:
414351
MPN:
LE600I
$112.87
Payment options

This product is currently not available!

Shipping Information
  • Unavailable for shipping
  • This product is not currently available for purchase
Store Availability
  • Unavailable at Bankstown Store
  • Unavailable at Castle Hill Store
  • Unavailable at Northmead Store
APC LE600I; Nominal input voltage: 230 V, Input frequency: 50/60 Hz; Output voltage: 220-240 V, Output frequency: 47/63 Hz, Output power capacity: 600 VA; AC outlets quantity: 4 AC outlet(s), AC outlet types: C13 coupler, Power plug: C14 coupler; Surge energy rating: 300 J, Efficiency: 92%; Weight: 3.1 kg, Width: 214 mm, Depth: 141 mm
Line-R 600VA Automatic Voltage Regulator

Automatic voltage regulation for protection against brownouts and overvoltages.

- Automatic Voltage Regulation (AVR)
Automatically steps up low voltage and steps down high voltage to levels that are suitable for your equipment.

- Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse.

- Lightning and Surge Protection
To prevent damage to your equipment from electric power surges and spikes.
Inputs
Nominal input voltage The voltage which the manufacturer recommends that the device needs to operate normally. 230 V
Input frequency The frequency (Hz) which is required to power the product. 50/60 Hz
Outputs
Output voltage 220-240 V
Output frequency 47/63 Hz
Output power capacity The maximum power that the device can produce. 600 VA
Output power The power that the device can produce. 600 W
Ports & interfaces
AC outlets quantity The number of sockets in the device where AC electrical power can be connected. 4 AC outlet(s)
AC outlet types The type of outlet for AC electricity. C13 coupler
Power plug A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection. C14 coupler
Power
Surge protection
Surge energy rating A surge protector is an appliance designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. The surge energy rating is a measure of how much energy a surge protector can theoretically absorb in a single event, without failure. 300 J
Efficiency 92%
Technical details
Product colour The colour e.g. red, blue, green, black, white. Beige, Gray
Rack mounting The type of mounting that can position devices in a shelving system (rack).
Power protection features Features that protect the device against power problems e.g. overload. Over voltage,Overload,Short circuit,Under voltage
Display
Built-in display A display which is part of the product, so you do not need to attach another display.
Weight & dimensions
Width The measurement or extent of something from side to side. 214 mm
Depth The distance from the front to the back of something. 141 mm
Height The measurement of the product from head to foot or from base to top. 116 mm
Weight Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies. 3.1 kg
Certificates
RoHS compliance The Restriction of Hazardous Substances (RoHS) Directive aims to restrict certain dangerous substances commonly used in electrical and electronic equipment. Any RoHS compliant product is tested for the presence of Lead (Pb), Cadmium (Cd), Mercury (Hg), Hexavalent chromium (Hex-Cr), Polybrominated biphenyls (PBB), and Polybrominated diphenyl ethers (PBDE). PBB and PBDE are flame retardants used in several plastics. For Cadmium and Hexavalent chromium, there must be less than 0.01% of the substance by weight at raw homogeneous materials level. For Lead, PBB, and PBDE, there must be no more than 0.1% of the material, when calculated by weight at raw homogeneous materials. Any RoHS compliant component must have 100 ppm or less of mercury and the mercury must not have been intentionally added to the component. In the EU, some military and medical equipment are exempt from RoHS compliance.
Certification CE
Operational conditions
Operating temperature (T-T) The minimum and maximum temperatures at which the product can be safely operated. 0 - 40 °C
Storage temperature (T-T) The minimum and maximum temperatures at which the product can be safely stored. -25 - 65 °C
Operating relative humidity (H-H) 5 - 95%
Storage relative humidity (H-H) 5 - 95%
Operating altitude 0 - 3000 m
Non-operating altitude 0 - 12000 m
Indication
LED indicators
Packaging content
Manual
Packaging data
Package dimensions (WxDxH) Dimensions of the packaged product (Width x Depth x Height). 273 x 207 x 175 mm
Package weight Weight of the packaged product. 3.4 kg
More Information
SKU 414351
MPN LE600I
Brand APC
Product Condition Brand New/Unused
Stock Availability Available for Shipping
Product Use General
Warranty Period 2 Years Warranty
Warranty Contact https://www.apc.com/