APC Basic 0U/1U, 120-240V/15A, 220-240V/10A PDU

Item No:
445160
MPN:
AP6015A
$129.00

APC Basic 0U/1U, 120-240V/15A, 220-240V/10A PDU

$129.00
Payment options
Shipping Information
  • Available for shipping
  • Usually leaves our partner warehouse in 2-4 business days
Store Availability
  • 3-5 business days at Bankstown Store
  • 3-5 business days at Castle Hill Store
  • 2-4 business days at Northmead Store
Shipping Estimate
Rack PDU, Basic, 0U/1U, 120-240V/15A, (8) C13, Black
The APC by Schneider Electric Basic Rack Power Distribution Unit (PDU) distributes power to devices in the rack.
Design
PDU types A power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing, and remote monitoring and control by LAN or SNMP. Basic
Rack capacity The spase that device fill in rack. 0U/1U
Mounting What size the mounting head of the product is, to couple it with a camera. Horizontal/Vertical
Product colour The colour e.g. red, blue, green, black, white. Black
Ports & interfaces
AC outlets quantity The number of sockets in the device where AC electrical power can be connected. 8 AC outlet(s)
AC outlet types The type of outlet for AC electricity. C13 coupler,C19 coupler
Features
Cable length How long the cable is. 3.65 m
RoHS compliance The Restriction of Hazardous Substances (RoHS) Directive aims to restrict certain dangerous substances commonly used in electrical and electronic equipment. Any RoHS compliant product is tested for the presence of Lead (Pb), Cadmium (Cd), Mercury (Hg), Hexavalent chromium (Hex-Cr), Polybrominated biphenyls (PBB), and Polybrominated diphenyl ethers (PBDE). PBB and PBDE are flame retardants used in several plastics. For Cadmium and Hexavalent chromium, there must be less than 0.01% of the substance by weight at raw homogeneous materials level. For Lead, PBB, and PBDE, there must be no more than 0.1% of the material, when calculated by weight at raw homogeneous materials. Any RoHS compliant component must have 100 ppm or less of mercury and the mercury must not have been intentionally added to the component. In the EU, some military and medical equipment are exempt from RoHS compliance.
Certification VDE, CE
Power
Nominal input voltage The voltage which the manufacturer recommends that the device needs to operate normally. 230 V
AC input frequency 50 - 60 Hz
Maximum current The greatest possible amount of current, which is a quantity representing the rate of flow of electric charge. 10 A
Nominal output voltage The voltage which the manufacturer states that the device can produce. 120 - 240 V
Load capacity 2300 VA
Maximum input current per phase 10 A
Maximum power The maximum power that can be put into or produced by the device. 2300 W
Operational conditions
Operating temperature (T-T) The minimum and maximum temperatures at which the product can be safely operated. 0 - 50 °C
Storage temperature (T-T) The minimum and maximum temperatures at which the product can be safely stored. -15 - 60 °C
Operating relative humidity (H-H) 5 - 95%
Storage relative humidity (H-H) 5 - 95%