APC Smart-UPS SC 450VA 230V 280W

Item No:
414519
MPN:
SC450RMI1U
$372.87
Delivery: Pre-order ETA 09/11/21
Pickup: Check availability
Payment options
APC Smart-UPS; UPS topology: Line-Interactive, Output power capacity: 450 VA, Output power: 280 W; AC outlet types: C13 coupler, Power plug: C14 coupler, AC outlets quantity: 4 AC outlet(s); Battery technology: Sealed Lead Acid (VRLA), Battery capacity: 108 VAh, Typical backup time at full load: 5.9 min; Form factor: Rackmount/Tower, Product colour: Gray, Rack capacity: 1U; Width: 432 mm, Depth: 383 mm, Height: 44 mm
The economical UPS to start your business
APC Smart-UPS SC is the perfect protection for the IT resources of your growing business. Manageable and cost effective, APC Smart-UPS SC is designed for use by small and medium companies looking to protect entry level servers and networking equipment, providing both power and data-line protection. Included PowerChute Business Edition management software allows you to configure safe system shutdowns and take advantage of advanced UPS management features like automated risk assessments and runtime capacity calculations. (All major operating systems supported). Communications are through your server's standard serial port. When you are ready to take your business to the next level you can use the same software environment found on Smart-UPS SC to seamlessly manage other Smart-UPS models, allowing you to grow your IT infrastructure without having to replace your software or retrain your administrators. Built on the same standards as the award winning Smart-UPS UPS, the Smart-UPS SC is the UPS to start your business with.

Features

UPS topology The two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
Line-Interactive
Output power capacity The maximum power that the device can produce.
450 VA
Output power The power that the device can produce.
280 W
Waveform
Sine
Input operation voltage (min) The minumum voltage needed by the device during operation.
151 V
Input operation voltage (max) The maximum input voltage supported by the device.
302 V
Input frequency The frequency (Hz) which is required to power the product.
50/60 Hz
Automatic Voltage Regulation (AVR)
Surge energy rating A surge protector is an appliance designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. The surge energy rating is a measure of how much energy a surge protector can theoretically absorb in a single event, without failure.
320 J
Hold time (min)
4 ms
Hold time (max)
8 ms
Noise level The amplitude level of the undesired background noise, usually measured in decibels (db).
38 dB
Surge protection
Surge protection features
Digital Subscriber Line (DSL),Fax,Modem,Network
Audible alarm(s) Alarms that make a sound when they are activated (set off).
Audible alarm modes
Low battery alarm,Overload alarm
Auto-restart

Ports & interfaces

AC outlet types The type of outlet for AC electricity.
C13 coupler
Power plug A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
C14 coupler
AC outlets quantity The number of sockets in the device where AC electrical power can be connected.
4 AC outlet(s)
Number of output IEC jumpers
2
Serial interface
Serial interface type
RS-232
Serial ports quantity The number of serial ports in a computer or peripheral. A serial port is a serial communication physical interface through which information transfers in or out one bit at a time. The term "serial port" usually identifies hardware more or less compliant to the RS-232 standard, intended to interface with a modem or with a similar communication device. In modern computers and peripherals, serial ports have largely been replaced by USBs and other interfaces.
1

Battery

Battery technology The type of battery in the device, e.g. nickel–cadmium (NiCd).
Sealed Lead Acid (VRLA)
Battery capacity
108 VAh
Typical backup time at full load The amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is fully loaded (100% of capacity).
5.9 min
Typical backup time at half load The amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity).
19.4 min
Battery life (max)
5 year(s)
Battery recharge time Approximate time required to recharge the battery from completely empty to completely full
5 h
Hot-swap battery
Automatic battery test

Design

Form factor The shape or design of the product.
Rackmount/Tower
Rack capacity The spase that device fill in rack.
1U
Product colour The colour e.g. red, blue, green, black, white.
Gray
LED indicators
Battery replacement
RoHS compliance The Restriction of Hazardous Substances (RoHS) Directive aims to restrict certain dangerous substances commonly used in electrical and electronic equipment. Any RoHS compliant product is tested for the presence of Lead (Pb), Cadmium (Cd), Mercury (Hg), Hexavalent chromium (Hex-Cr), Polybrominated biphenyls (PBB), and Polybrominated diphenyl ethers (PBDE). PBB and PBDE are flame retardants used in several plastics. For Cadmium and Hexavalent chromium, there must be less than 0.01% of the substance by weight at raw homogeneous materials level. For Lead, PBB, and PBDE, there must be no more than 0.1% of the material, when calculated by weight at raw homogeneous materials. Any RoHS compliant component must have 100 ppm or less of mercury and the mercury must not have been intentionally added to the component. In the EU, some military and medical equipment are exempt from RoHS compliance.
Certification
C-tick, CE, GOST, VDE, PEP, EOLI

Operational conditions

Operating temperature (T-T) The minimum and maximum temperatures at which the product can be safely operated.
0 - 40 °C
Storage temperature (T-T) The minimum and maximum temperatures at which the product can be safely stored.
-15 - 45 °C
Operating relative humidity (H-H)
0 - 95%
Storage relative humidity (H-H)
0 - 95%
Operating altitude
0 - 3000 m
Non-operating altitude
0 - 15000 m

Weight & dimensions

Width The measurement or extent of something from side to side.
432 mm
Depth The distance from the front to the back of something.
383 mm
Height The measurement of the product from head to foot or from base to top.
44 mm
Weight Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
10.2 kg

Packaging data

Rack mount kit
Cables included
RS-232
Manual
Software CD
Package width The distance from one side of the packaging to the other.
476 mm
Package depth The distance from the front to the back of the packaging.
589 mm
Package height The distance from the top to the bottom of the packaging.
164 mm
Package weight Weight of the packaged product.
11.7 kg

Logistics data

Quantity per pallet Quantity of a single product per pallet. If more than one product is packed per carton; this is the number of products (not number of cartons) per shipping pallet.
24 pc(s)

Other features

Nominal output voltage The voltage which the manufacturer states that the device can produce.
230 V
Specifications
SKU 414519
MPN SC450RMI1U
Brand APC
Product Condition Brand New/Unused
Product Use General