APC Smart-UPS 3000VA 2U RackMount 230V 2700W With SmartConnect

Item No:
414652
MPN:
SMT3000RMI2UC
$3,047.87
Delivery: Pre-order ETA 27/12/21
Pickup: Check availability
Payment options
APC SMT3000RMI2UC; UPS topology: Line-Interactive, Output power capacity: 3000 VA, Output power: 2700 W; AC outlet types: C13 coupler,C19 coupler, Power plug: C20 coupler, AC outlets quantity: 9 AC outlet(s); Battery technology: Sealed Lead Acid (VRLA), Battery capacity: 547 VAh, Typical backup time at full load: 3.2 min; Form factor: Rackmount, Product colour: Black, Rack capacity: 2U; Width: 480 mm, Depth: 683 mm, Height: 86 mm
Adjustable voltage sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.

Adjustable voltage-transfer points
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.

Audible alarms
Provides notification of changing utility power and UPS power conditions

Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.

Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.

Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance

Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).

Cold-start capable
Provides temporary battery power when the utility power is out.

Disconnected battery notification
Warns when a battery is not available to provide backup power.

Energy meter
Provides actual kilowatt hours of usage for energy conscious users.

Frequency and voltage regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.

Green mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.

High online efficiency
Reduces utility costs, generates less heat.

Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced

Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.

Intuitive LCD interface
Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.

LED Indicators
Provide easy-to-read status of the unit and utility power conditions.

Network manageable
Provides remote power management of the UPS over the network.

Outlet group control
Turn on/off, reboot or shut down select outlet groups to save dispatching technicians to remote locations (for UPSs with switched outlet groups).

Predictive failure notification.
Provides early-warning fault analysis ensuring proactive component replacement.

Predictive replace battery date
Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.

Pure sine wave output on battery
Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.

Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Sequenced network shutdown and reboot
Customize network shutdown and reboot sequence of connected servers and UPSs.

Serial connectivity
Provides management of the UPS via a serial port.

Single switched outlet group
Single outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.

SmartConnect
Innovative, easy to use remote monitoring feature that provides automatic notifications, firmware updates, and advanced support services.

StruxureWare Data Center Expert compatible
Enables centralized management via StruxureWare Data Center Expert.

Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.

USB connectivity
Provides management of the UPS via a USB port (not available on all models).

User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)

Wide input voltage range
Designed for harsh electrical environments to save battery life.

Features

UPS topology The two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
Line-Interactive
Output power capacity The maximum power that the device can produce.
3000 VA
Output power The power that the device can produce.
2700 W
Waveform
Sine
Input operation voltage (min) The minumum voltage needed by the device during operation.
151 V
Input operation voltage (max) The maximum input voltage supported by the device.
302 V
Input frequency The frequency (Hz) which is required to power the product.
50/60 Hz
Output operation voltage (min) The minumum voltage produced by the device during operation.
220 V
Output operation voltage (max) The maximum output voltage produced by the device.
240 V
Automatic Voltage Regulation (AVR)
Surge energy rating A surge protector is an appliance designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. The surge energy rating is a measure of how much energy a surge protector can theoretically absorb in a single event, without failure.
320 J
Hold time (min)
4 ms
Hold time (max)
8 ms
Efficiency
98.9%
Noise level The amplitude level of the undesired background noise, usually measured in decibels (db).
55 dB
Audible alarm(s) Alarms that make a sound when they are activated (set off).
Auto-restart

Ports & interfaces

AC outlet types The type of outlet for AC electricity.
C13 coupler,C19 coupler
Power plug A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
C20 coupler
AC outlets quantity The number of sockets in the device where AC electrical power can be connected.
9 AC outlet(s)
Number of output IEC jumpers
3
USB port The device features a socket into which a USB cable can be plugged.
Serial interface
Serial interface type
RJ-45
SmartSlot

Battery

Battery technology The type of battery in the device, e.g. nickel–cadmium (NiCd).
Sealed Lead Acid (VRLA)
Battery capacity
547 VAh
Typical backup time at full load The amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is fully loaded (100% of capacity).
3.2 min
Typical backup time at half load The amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity).
11.5 min
Battery life (max)
5 year(s)
Battery recharge time Approximate time required to recharge the battery from completely empty to completely full
3 h
Hot-swap battery
Automatic battery test
Cold start

Design

Form factor The shape or design of the product.
Rackmount
Rack capacity The spase that device fill in rack.
2U
Cable length How long the cable is.
2 m
Product colour The colour e.g. red, blue, green, black, white.
Black
LED indicators
Status
Display The description of display that can includes display type, resolution, size etc.
LCD
RoHS compliance The Restriction of Hazardous Substances (RoHS) Directive aims to restrict certain dangerous substances commonly used in electrical and electronic equipment. Any RoHS compliant product is tested for the presence of Lead (Pb), Cadmium (Cd), Mercury (Hg), Hexavalent chromium (Hex-Cr), Polybrominated biphenyls (PBB), and Polybrominated diphenyl ethers (PBDE). PBB and PBDE are flame retardants used in several plastics. For Cadmium and Hexavalent chromium, there must be less than 0.01% of the substance by weight at raw homogeneous materials level. For Lead, PBB, and PBDE, there must be no more than 0.1% of the material, when calculated by weight at raw homogeneous materials. Any RoHS compliant component must have 100 ppm or less of mercury and the mercury must not have been intentionally added to the component. In the EU, some military and medical equipment are exempt from RoHS compliance.
Certification
CE, EAC, EN 60950, EN/IEC 62040-1, EN/IEC 62040-2, GS Mark, IRAM, RCM, VDE, WEEE, REACH, PEP, EOLI

Operational conditions

Operating temperature (T-T) The minimum and maximum temperatures at which the product can be safely operated.
0 - 40 °C
Storage temperature (T-T) The minimum and maximum temperatures at which the product can be safely stored.
-15 - 45 °C
Operating relative humidity (H-H)
0 - 95%
Storage relative humidity (H-H)
0 - 95%
Operating altitude
0 - 3000 m
Non-operating altitude
0 - 15000 m

Weight & dimensions

Width The measurement or extent of something from side to side.
480 mm
Depth The distance from the front to the back of something.
683 mm
Height The measurement of the product from head to foot or from base to top.
86 mm
Weight Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
44.3 kg

Packaging data

Rack mount kit
Cables included
RS-232,USB cable
Quick installation guide
Software CD
Bundled software Software distributed with another product such as a piece of computer hardware or other electronic device, or a group of software packages which are sold together. A software suite is an example of bundled software, as is software which is pre-installed on a new computer.
Powershute Business Edition
Package width The distance from one side of the packaging to the other.
600 mm
Package depth The distance from the front to the back of the packaging.
980 mm
Package height The distance from the top to the bottom of the packaging.
254 mm
Package weight Weight of the packaged product.
51.7 kg

Other features

Nominal output voltage The voltage which the manufacturer states that the device can produce.
230 V
Nominal input voltage The voltage which the manufacturer recommends that the device needs to operate normally.
230 V
Specifications
SKU 414652
MPN SMT3000RMI2UC
Brand APC
Product Condition Brand New/Unused
Product Use General